Safety 

  

The  following  safety  precautions  must  be  taken  into  account  in  order  to  avoid  injury  to 
personnel or damage to the environment or to the Lifa Duct Control Cleaning Robot itself.   
  
Following these instructions will ensure the safe and uninterrupted use of the machine.  

  

  The  Lifa  Duct  Control  Cleaning  Robot  is  both  electrically  and  pneumatically  operated  unit. 

The electrical power for the Duct Control Cleaning robot’s drive-motor come from the battery 
of the  Duct  Control  Manual  or  Mini.  The  battery of  Duct  Control  Manual  or  Mini  should  be 
charged every day after using and stored with fully charged battery only. 

 

  The 12 V battery of Duct Control Manual or Mini should be charged by the original charger 

connected to a single phase 110/230 V, 50/60 Hz.  
 

  The constant air flow for running the brush motor must have 340 l/minute in 7 bar pressure. 

Use only approved hoses for compressed air. 

 

  The equipment must not be positioned or used in places where there is a risk of explosion or 

hazardous substances.  

 

 

The equipment must not get wet and it has to be protected from moisture, vibration 
and wind.   

 

  Foreign objects must not be inserted or fitted into the equipment.  

 

  The machine cannot be covered during the use  

 

  The  user  must  ensure  that  the  appliance  is  adjusted  for  the  task  and  that  the  statutory 

requirements are met.   

 

  Be careful with sharp edges in the ductwork.  

 

  Use only accepted ladders or stands when working with Duct Control Cleaning Robot.  

 

  Wear  protective  mask,  eye  protection  glasses,  overall,  gloves  shoes  etc.  according  to  the 

requirements of the working place/environment.    

 

  In any questions, contact Lifa Air Ltd, or an authorized dealer. 

 
 

Summary of Contents for LIFA Duct Control Cleaning Robot

Page 1: ...inspection camera robot operated with electricity and compressed air for circular and rectangular ducts These instructions must always be available to personnel using the equipment Please read instru...

Page 2: ...directions 3 Lifa Duct Cleaning Robot 4 Technical information 4 Principle of operations 6 Safety 7 Construction and Installation 9 Driving the robot with Duct Control Manual or Mini 10 Spare parts 13...

Page 3: ...have read the operating and other instructions supplied by the manufacturer The persons responsible for operating the machines or equipment must acquaint themselves with their structure functions and...

Page 4: ...mpressed Air Brush motor Pneumatic motor Rotating speed of the brush Step less up until 800 rpm Sound 79 2 dB A ISO CD 15 744 Air consumption of the motor 340 l min 7 bar 100psi The required compresso...

Page 5: ...ls for height control and other operation The pneumatic system also enables a compressed air operating remote controlled spraying of chemicals or air jetting instead of brush rotation when needed The...

Page 6: ...manufacturer for both the TFT monitor and video grabber picture card recommended by Lifa Air Ltd Driving Before any operation train yourself by driving on the floor and under the furniture to be able...

Page 7: ...ged by the original charger connected to a single phase 110 230 V 50 60 Hz The constant air flow for running the brush motor must have 340 l minute in 7 bar pressure Use only approved hoses for compre...

Page 8: ...es and controls the robot in the duct and another who feeds draws the cables electrical cable and pneumatic hose 4 The safety of the working environment Make sure that the lightning air conditioning l...

Page 9: ...nozzles one air and one liquid nozzle 2 Duct Control Mini or Manual in a plastic case Connection Central Box Main power supply control fuse breaker Power on off switch Input for video steering cable I...

Page 10: ...ing forward turn joystick forward Driving backward turn joystick backward Turning left turn joystick left Turning right turn joystick right Try driving first on safe and open place in order to learn h...

Page 11: ...al box will light up if the power supply is OK The battery at Duct Control Manual or Mini central box must be charged with a CE marked charger that is connected to single phase current 110 230 V 50 60...

Page 12: ...OF THE MACHINE The following maintenance and upkeep work has to be done in regular basis depending on the purpose of which the machine has been used This enables a trouble free use General cleanlines...

Page 13: ...e minute to clean the hose from excessive oil Wurth Rost Off Plus WD 40 CRC 5 56 or analog THE MAINTENANCE OF THE CAMERA When winding the cable back to the reel after use always try to get all the twi...

Page 14: ...mpressors to pneumatic brushing machine Including 2 connecting hoses 1 5 m 6420281023651 Connection hose 25m on reel air or liquid 6420281024566 High volume air jetting Nozzle including fast coupling...

Page 15: ...motor isn t stuck by rotating it with e g a wrench from the brush adapter The motor should rotate considerably freely So do not use excessive force If the motor does not rotate freely do the procedur...

Page 16: ...rer or by an authorized representative of the manufacturer Manufacturer does not accept responsibility for maintenance carried out by a third party A written reclamation form must be filled out and se...

Page 17: ...sibility that the machine models covered by this announcement comply with the requirements of the following EC directives and standards EU Low Voltage Directive LVD 2014 35 EY EU Electromagnetic Compa...

Reviews: