15. Do not plug appliances, such as hair dryers or heaters into UPS receptacles. 

 

 

16. Operate UPS only from a grounded outlet (2 wire plus ground) 120 VAC, 60/50 Hz.  

 

17. The UPS is equipped with a grounded NEMA 5-15 input power plug.  Do not defeat 

the safety purpose of this plug.  If unable to fully insert the plug into the outlet, contact 
an electrician.  All utility receptacles must be grounded as well.  

 

18. Route power supply cords so they are not walked on or pinched.  

 

19. Never block or insert any object into ventilation holes or other openings.  Maintain a 

minimum clearance of 4” all around UPS for proper air flow and cooling.  

 

20. CAUTION: Do not open or mutilate battery.  Released electrolyte is harmful to skin 

and eyes and may be toxic.  

 

21. CAUTION: This UPS complies with the limits for a Class A digital device, pursuant to 

Subpart J of Part 15 of FCC rules.  These limits provide reasonable protection against 
harmful interference in a commercial environment.  This UPS generates, uses, and 
radiates radio frequency energy and, if not installed and used in accordance with the 
instruction manual, may cause harmful interference to radio communications.  
Operation of this UPS in a residential area is likely to cause harmful interference which 
the user must correct at his own expense.  

 

INTRODUCTION & SYSTEM DESCRIPTION 

 
Congratulations on choosing the Liebert UPStation® GX UPS.  It provides continuous, 
conditioned power to microcomputers and other data processing equipment.  

 

Upon generation, AC power is clean and stable.  However, during transmission, it may be 
subject to load variations or accidents that cause power problems like low voltage, voltage 
spikes, or complete power failure.  These problems may interrupt computer operations, 
cause data loss, or even damage equipment.  

 

The UPS protects against many of these disturbances.  It smoothes out voltage variations 
and during complete power failure, supports equipment long enough for an orderly 
shutdown.  These compact units are available in three ratings: 1000, 1500, and 2100 VA.  
This manual includes specifications for each model.  

 

The UPStation® GX is a compact ”on-line” UPS that supplies critical equipment with 
continuous premium, computer-grade power.  An ”On-line” UPS continuously generates 
and regulates output power, whether utility power is present or not.  In contrast, a ”standby” 
UPS only generates output power when utility power fails.  

 

The UPStation® GX supplies critical equipment with clean, sinewave power to simulate 
utility-generated power.  Equipment like computers, monitors, printers, phone systems, and 
laboratory instruments operate best on sinewave power.  

 

The LED bar displays indicate ”percentage load” and ”battery capaci
two levels of alarms during battery operation, self-diagnostics, and a combination battery 
test / alarm silence switch.  

 

To allow communications between the UPS and a LAN server or other computer system, 
the UPStation’ GX UPS is equipped with an RS-232 interface port.  This port provides 
detailed operating information including voltages, currents, temperature, and alarm status 
to the host system when used with Liebert SiteNet soft- ware.  In addition, this port allows 
remote programming of UPS operation and numerous internal operating parameters. 

Summary of Contents for UPStation 1000 VA GX

Page 1: ...POWER PROTECTION 1000 VA to 3000 VA UPStation GX R...

Page 2: ...ULTER LES CODES LOCAUX 8 WARNING TO REDUCE RISK OF FIRE OR ELECTRIC SHOCK INSTALL IN A TEMPERATURE AND HUMIDITY CONTROLLED AREA FREE FROM CONDUCTIVE CONTAMINANTS 9 AVERTISSEMENT POUR REDUIRE LE RISQUE...

Page 3: ...stable However during transmission it may be subject to load variations or accidents that cause power problems like low voltage voltage spikes or complete power failure These problems may interrupt c...

Page 4: ...h normal charging They maintain UPS output at full rated power for 10 minutes Reducing the load increases battery back up time Bypass This standard UPStation GX feature provides an alternate power sou...

Page 5: ...Locate UPS where it cannot be accidentally turned off in an area free of moisture flammable liquids gases or corrosives RACKMOUNT INSTALLATION 1 Turn the ON OFF switch at the front of the UPS OFF Rem...

Page 6: ...cabinets plug the power cable of the second battery cabinet into the battery connector of the first battery cabinet UPS OPERATION Normal Mode Normally the utility supplies UPS power The UPS filters a...

Page 7: ...e when batteries have not fully recharged If after 4 hours of recharge or in the test mode the 3 left most LEDs still flash contact Liebert Technical Support at 1 800 222 5877 and ask about replacemen...

Page 8: ...N for normal operation after initial start up 4 Output Voltage Selector 3000VAONLY This switch on the rear of the unit allows choice of 208 or 240 VAC NOTE The output must match the input if bypass is...

Page 9: ...DB 25 port provides several signals listed below by pin number PIN FUNCTION PIN FUNCTION 1 Reserved 14 On Inverter active low 2 RxD 15 On UPS active closed 3 TxD 16 On battery active closed 4 Not Used...

Page 10: ...lation prolonged overloads or high temperature environments may cause overheating Immediately save work in process and correct the problem TROUBLESHOOTING If the UPS shuts down due to a fault conditio...

Page 11: ...ate critical applications and save data Shutdown all loads and the UPS Batteries uncharged Reduced battery time Batteries unable to hold charge due to age Plug UPS in and turn ON for a minimum of 4 ho...

Page 12: ...is manual at all times Call Liebert Technical Support at 1 800 222 5877 for battery replacement instructions Battery Safety Precautions WARNING Battery maintenance procedures expose hazardous live par...

Page 13: ...MA 5 15R 2 Duplex 4 NEMA 5 15R 2 Duplex 2 NEMA 5 20R 1 Duplex BATTERY Backup w Int Battery Only 10 Minutes Backup w 1 Ext Cabinet 90 Minutes 40 Minutes Backup w 2 Ext Cabinets 160 Minutes 90 Minutes B...

Page 14: ...ull Load Amps for 1 Sec Bypass Transfer 4 6 Milliseconds Efficiency AC to AC 85 at 100 Load Receptacles 4 NEMA 5 15R 2 Duplex 1 NEMA L6 30 1 NEMA L12 20 BATTERY Backup w 1 Ext Cabinet 10 Minutes Backu...

Page 15: ...ill Liebert be responsible beyond the purchase price of the product SELLER DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY OF THE GOODS OR THE FITNESS OF THE GOODS FOR ANY INTENDED PURPOSES LIEBERT...

Page 16: ...g and UPS with power ranges from 250 VA to more than 1000 kVA Integrated systems that provide both environmental and power protection in a single flexible package Monitoring and control on site or rem...

Reviews: