Battery Run Times

Product Warranty Registration

To register for warranty protection:
• Visit  the 

Quick Links

 section of our Web site at:

http://www.liebert.com

 

• Click on 

Product Warranty Registration

 and fill in the form.

If you have any questions, please contact us at:

US: 800-222-5877

Outside the US: 614-841-6755

[email protected]

AGENCY

Safety

UL 1778, c-UL Listed

Surge

ANSI C62.41, Category A, Level 3

(IEEE 587, Category A);

EN61000-4-5, Level 3, Criteria A

ESD

EN61000-4-2, Level 3, Criteria A

Susceptibility

EN61000-4-3, Level 3, Criteria A

Electrical Fast 

Transient/Burst

EN61000-4-4, Level 4, Criteria A

Emissions

FCC Part 15, Subpart B, Class B

Conducted Immunity

EN61000-4-6, Level 3, Criteria A

Harmonics

EN61000-3-2

Flicker

EN61000-3-3

Transportation

ISTA Procedure 1A

Load %

350VA

500VA

650VA

5

319

156

192

10

146

113

95

20

75

49

42

30

45

31

30

40

35

22

21

50

24

17

14

60

20

11

13

70

17

9

10

80

13

7

7

90

10

5

6

100

9

4

5

NOTE

Approximate discharge times are in minutes and at 77°F 

(25°C) with a resistive load.

Summary of Contents for PowerSure PSP350MT-120

Page 1: ...POWER AVAILABILITY POWERSURE PSP USER MANUAL 350 650 VA 120V...

Page 2: ......

Page 3: ...1 ON OFF Alarm Silence Button 11 Status Indicators Fault Utility Battery 12 Utility Indicator Green 12 Battery Indicator Green Amber 12 Fault Indicator Red Green 12 Location and Status of Indicators 1...

Page 4: ...PS 18 Maintaining Batteries 18 Battery Replacement 18 Battery Replacement Procedure 19 TROUBLESHOOTING 20 Guide to Status Indicators 20 Troubleshooting Chart 21 SPECIFICATIONS 22 Battery Run Times 23...

Page 5: ...and corrosive substances Operate the UPS only from a properly grounded earthed 110 127 VAC 50Hz or 60Hz AC supply To reduce the risk of electric shock do not remove the cover as it has no user service...

Page 6: ...ons turn off and unplug your UPS from the outlet and contact your local dealer Liebert representative or Liebert Worldwide Support Group The power cord or plug is damaged Liquid has been spilled on th...

Page 7: ...ordance with local regulations NOTE This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this...

Page 8: ...S designed for desktop applications It provides perfect one to one power protection for electronic equipment such as PCs point of sale displays home office equipment and similar electronic gear The Po...

Page 9: ...5 Front View of UPS Power ON OFF Alarm Silence Battery Indicator Green Amber Fault Indicator Red Green Utility Indicator Green For details see Controls and Indicators section...

Page 10: ...les 4 Battery backup surge protection Black output receptacles 2 Surge protection only Site Wiring Fault Indicator Red Data Line Protection Connectors 2 Phone Fax DSL Internet Modem devices Battery co...

Page 11: ...harger In Normal mode the Battery Charger converts utility AC power into regulated DC power to float charge the battery It is continuously charging the battery whenever the UPS is plugged into a power...

Page 12: ...Start guide PowerSure family user manual on CD Warranty card MultiLink software CD MultiLink serial cable M3LS9P9S 10 ft 3m RJ 11 cord 7 ft 2 1 m USB cable 6 ft 1 8m MultiLink serial cable M3LS9P9S 10...

Page 13: ...mperature range of 32 F to 104 F 0 C to 40 C 3 Plug the PowerSure PSP s attached 6 ft 1 8m power cord into an AC outlet Check that the Site Wiring Fault Indicator on the rear is not illuminated If lit...

Page 14: ...ll as the user manual are on the CD included in the PowerSure PSP package Option 2 Contact Closure Communications Contact Closure communications provides on battery and low bat tery signals for orderl...

Page 15: ...pressing the main ON OFF button for more than two 2 seconds will shut down the UPS An audible alarm sounds briefly Alarm Silence When a UPS alarm is active pressing and releasing the main ON OFF butt...

Page 16: ...nnected loads Battery Indicator Green Amber The Battery Indicator illuminates to indicate the UPS is operating on battery green or to signify a battery warning amber Fault Indicator Red Green The Faul...

Page 17: ...fault set tings are 100VAC 135VAC DIP switch positions for each voltage set ting are as follows DIP switch settings Left Right Nominal Utility Setting Up Up 120VAC 100 135VAC default Up Down 110VAC 10...

Page 18: ...en the UPS is in Normal mode the Utility Indicator illuminates green The PowerSure PSP continuously monitors the batteries to maintain them in a fully charged state The battery charger operates whenev...

Page 19: ...ing amber and the alarm sounds every half second Low battery warning is defaulted to two 2 minutes but can be configured via Mul tiLink For more information refer to Troubleshooting section CAUTION Tu...

Page 20: ...own the UPS after gracefully shutting down the operating system on the host computer system when the remaining battery run time is low The timing of the signal depends on MultiLink s configuration set...

Page 21: ...il the end of 2 minutes and then the UPS turns off The UPS must remain off for at least 10 seconds By default autorestart is enabled so the UPS will restart after 10 seconds If autorestart is disabled...

Page 22: ...charge of the batteries Battery Replacement This UPS is equipped with internal hot swappable batteries that the user can replace without shutting down the UPS or connected loads CAUTION A battery can...

Page 23: ...ckwise as shown below 3 Disconnect the insulated connectors from the battery terminals 4 Insert a new battery pack and push the connectors onto the battery terminals black to black red to red NOTE The...

Page 24: ...agnosis Audible Alarm Green ON Normal operation with utility power present no beep Green ON UPS is operating on battery beep every 10 seconds Green ON Battery test has been initiated no beep Green ON...

Page 25: ...or have the utility checked by a qualified electrician AC overvoltage Wait until voltage lowers to an appropriate level or have the utility checked by a qualified electrician UPS shuts down Fault Indi...

Page 26: ...acles 4 NEMA 5 15R orange Battery backup surge protection 2 NEMA 5 15R black Surge protection Voltage Battery mode 120VAC 8 Output Current 2 9 A 4 2 A 5 4 A Waveform Battery mode Stepped Sinewave Freq...

Page 27: ...IEEE 587 Category A EN61000 4 5 Level 3 Criteria A ESD EN61000 4 2 Level 3 Criteria A Susceptibility EN61000 4 3 Level 3 Criteria A Electrical Fast Transient Burst EN61000 4 4 Level 4 Criteria A Emiss...

Page 28: ...24...

Page 29: ...sired location 3 Drill holes where cross hairs are located on template 4 Remove template and mount screws using 3 8 or M4 screws Distance from head of screw to wall should be 0 25 or 6 4mm 5 Mount Pow...

Page 30: ......

Page 31: ......

Page 32: ...for sensitive electronics Environmental systems close control air conditioning from 1 to 60 tons Power conditioning and UPS with power ranges from 300VA to more than 1000kVA Integrated systems that pr...

Reviews: