background image

1

I

MPORTANT

 S

AFETY

 I

NSTRUCTIONS

SAVE THESE INSTRUCTIONS

This manual contains important safety instructions that should be followed during the installation 

and maintenance of the UPS and batteries. Please read this manual thoroughly before attempting to 

install or operate this UPS. 

CONDITIONS OF USE:

 The input receptacle must be within 10 feet (3 meters) of the UPS.

Your UPS provides conditioned power to connected equipment. Maximum load must not exceed that 

shown on UPS rating label. If uncertain, consult your local dealer, Liebert representative or the Lie-

bert Worldwide Support Group.
Placing magnetic storage media on top of the UPS may result in data corruption.
The equipment can be installed and operated by individuals without previous training.

!

WARNING

SAFETY PRECAUTIONS
To prevent the risk of fire or electric shock, install the UPS in a temperature and humidity 

controlled room, free of conductive contaminants, moisture, flammable liquids, gases and 

corrosive substances.
Operate the UPS only from a properly grounded (earthed) 110-127 VAC, 50Hz or 60Hz AC 

supply.
To reduce the risk of electric shock, do not remove the cover, as it has no user-serviceable 

parts inside except the internal battery pack. Some components are live, even when AC power 

is disconnected. For service, contact a qualified technician.

!

CAUTION

Although your UPS has been designed and manufactured to ensure personal safety, improper 

use can result in electrical shock or fire. To ensure safety, please observe the following rules:
• Turn Off and unplug your UPS before cleaning. Do not use liquid or aerosol cleaners. A dry 

cloth is recommended to remove dust from the surface of your UPS.

• Do not install or operate your UPS in or near water.
• Do not place UPS on an unstable cart, stand or table.
• Do not place UPS under direct sunlight or close to heat emitting sources.
• Never block or insert any objects into the ventilation holes or other openings of the UPS. 

Keep all vents free of dust accumulation that could restrict air flow.

• Do not place UPS power cord in any area where it may get damaged by heavy objects.

!

WARNING

If your UPS demonstrates any of the following conditions, turn Off and unplug your UPS from 

the outlet and contact your local dealer, Liebert representative or Liebert Worldwide Support 

Group:
• The power cord or plug is damaged.
• Liquid has been spilled on the UPS.
• The circuit protector trips frequently.
• The UPS does not operate in accordance with the user manual.

!

CAUTION

DO NOT CONNECT equipment that could overload the UPS or demand half-wave 

rectification from the UPS, for example: electric drills, vacuum cleaners, laserjet/inkjet 

printers, hair dryers, overhead projectors.

Summary of Contents for PowerSure PSI 1000 - 3000VA 60 Hz 120V

Page 1: ...Power Protection for Business Critical Continuity Liebert PowerSure PSI User Manual 1000 3000VA 60 Hz 120V...

Page 2: ......

Page 3: ...nly 7 4 0 WHAT S INCLUDED 8 5 0 INSTALLATION 9 5 1 Preparation 9 5 2 Tower UPS Installation 9 5 3 Rack Mount UPS Conversion and Installation 10 5 4 External Battery Cabinet Installation 13 6 0 CONTROL...

Page 4: ...Battery Mode Shutdown Via Pins 4 5 19 8 3 USB Interface Port 20 8 4 Data Line Protection Connectors 20 8 5 UPS Intelligent Communications 20 9 0 VOLTAGE PROGRAMMING PROCEDURE 21 10 0 MAINTENANCE 22 1...

Page 5: ...assemblies 11 Figure 11 REPO switch connections 13 Figure 12 Load level indicators 4 green 1 amber 15 Figure 13 Battery level indicators 5 green 15 Figure 14 Normal mode operation with 26 50 load 17 F...

Page 6: ...iv...

Page 7: ...ve even when AC power is disconnected For service contact a qualified technician CAUTION Although your UPS has been designed and manufactured to ensure personal safety improper use can result in elect...

Page 8: ...cordance with local regulations NOTE This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this...

Page 9: ...tion followed by important instructions Requests the user to consult the manual Indicates the unit contains a valve regulated lead acid battery Recycle DC voltage Equipment grounding conductor Bonded...

Page 10: ...e utility Sensitive electronic equipment operates best from sinewave power For ease of use the PowerSure PSI contains Status Indicators to display Load Level Battery Level Buck Boost Over Temperature...

Page 11: ...C 72V 30A 1 2 3 4 INTELLISLOT 15A 120VAC LOAD 2 BREAKER LOAD 1 BREAKER IN OUT REPO RS 232 Data Line Connectors Circuit Breaker USB Port RS232 DB 9 Port Intellislot Port Attached Power Cord 10ft 3m REP...

Page 12: ...uency interference RFI They minimize surges or interference present in the utility line and keep the sensitive equipment protected 3 2 Relay In Normal mode the Relay passes utility AC power to the con...

Page 13: ...ets are available to extend battery run times 3 6 Inverter 1000 1440 Models Only In battery mode operation the inverter utilizes the DC output of the battery and inverts it into pre cise regulated sin...

Page 14: ...e 10 ft 3m USB cable 6 ft 1 8m RJ 11 cord 7 ft 2 1m Rack mount handles Support base Fixed rails Mounting hardware screws washers Front bezel Vertical display overlay MultiLink software CD RJ 11 cord 7...

Page 15: ...e instructions in either Tower UPS Installation or Rack Mount UPS Conversion and Installation 5 2 Tower UPS Installation When using the PowerSure PSI in a tower configuration use the included support...

Page 16: ...nt the UPS or battery cabinet Make sure fixed rails are at the same mounting height on each of the four 4 rack mounting rails NOTE When rack mounted the UPS must be supported by a shelf slide rails br...

Page 17: ...e front of the UPS to rack mounting rails to prevent the UPS from sliding out of position 11 Plug the PowerSure PSI s attached 10 ft 3m power cord into a dedicated wall receptacle properly protected b...

Page 18: ...r computer The PSI will work automatically with your built in power management software on Windows XP and 2000 and Mac OS 10 2 or later see 8 3 USB Interface Port for details Option 4 Intellislot The...

Page 19: ...cluded with the UPS for the tower option to prevent tip over One additional set of support base spacers ships with each external battery cabinet 5 Connect the supplied external battery cabinet cable t...

Page 20: ...will remain silenced until a new alarm condition is detected Battery Test To initiate a manual battery test press the ON Alarm Silence Battery Test button for at least one second while operating from...

Page 21: ...de The Battery Level Indicators are displayed in 20 increments as shown in Figure 13 Figure 13 Battery level indicators 5 green The PowerSure PSI is equipped with automatic and remote battery test fea...

Page 22: ...UPS detects an over temperature condition This indicator illuminates when the UPS shuts down due to an over temperature condition see Troubleshooting section for details 6 10 Fault Indicator Red The...

Page 23: ...the UPS is switched Off By default the UPS is set to perform an automatic battery test after it has been operating continuously for two 2 weeks The automatic battery test can be disabled via MultiLink...

Page 24: ...w battery condition occurs the Battery Indicator flashes green and the alarm sounds every half second The default low battery warning is two 2 minutes but can be configured via MultiLink For more info...

Page 25: ...nd 5 of the DB 9 connector 8 2 1 Any Mode Shutdown Via Pins 5 6 When Pin 6 is shorted to Pin 5 the UPS output is shut Off regardless of what mode the UPS is oper ating in The UPS cannot be started as...

Page 26: ...tionally MultiLink can be configured to coordinate shutdown across the network with other computers running MultiLink when you purchase a MultiLink License Kit For more information about the Intellisl...

Page 27: ...nitially the 0 25 Load Level Indicator will be flashing indicating the default setting of 120V as shown in Figure 18 5 Press the ON button to step through the voltage settings until the appropriate Lo...

Page 28: ...teries 10 3 Battery Replacement CAUTION A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed before replacing the batteries Remo...

Page 29: ...ssembly taking care not to destroy the packing Compare new and old battery assemblies to make sure they are the same If so proceed with Step 7 otherwise STOP and contact your local dealer Liebert repr...

Page 30: ...alarm sounds alerting that the UPS requires attention The alarm can be silenced except for low battery overload warning and over temperature warning conditions 2 One or more additional indicators will...

Page 31: ...Indicator Lit continuous beep Contact your local dealer Liebert representative or the Liebert Worldwide Support Group UPS shutdown due to a command from the communications port s Load Level 0 25 Indi...

Page 32: ...5 15R 8 NEMA 5 15R 6 NEMA 5 15 R 2 NEMA 5 20 R T Slot accepts 15APlug 6 NEMA 5 15 R 2 NEMA 5 20 R T Slot accepts 15APlug 4 NEMA 5 15 R 2 NEMA 5 20 R T Slot accepts 15A Plug 1 NEMA L5 30 R Voltage Norm...

Page 33: ...x 430 3 43 x 24 1 x 17 87 x 612 x 430 Shipping 11 8 x 27 8 x 23 5 300 x 706 x 598 13 1 x 34 x 23 5 333 x 864 x 598 Weight lbs kg Unit 66 1 30 101 4 46 Shipping 85 1 38 6 118 1 53 6 Battery Parameter T...

Page 34: ...493 444 20 409 283 307 291 249 30 283 219 243 222 168 40 248 177 197 194 148 50 209 133 163 150 129 60 166 122 141 137 114 70 136 98 128 122 92 80 127 84 115 107 71 90 110 64 102 92 56 100 98 56 89 7...

Page 35: ...or warranty protection visit the Quick Links section of our Web site at www liebert com Click on Product Warranty Registration and complete the form If you have any questions please contact us at US 8...

Page 36: ...ert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions 2006 Liebert Corporation All rights reserved thr...

Reviews: