background image

6  GB/IE/NI

7. Scope of delivery

1

2

3

4

   

5

6

   

7

8

1

  1 weather station with stand

2

   1 wind gauge with integrated temperature and 

air humidity sensor

3

  1 rain gauge with leaf filter

4

  6 screws suitable for ø 5 mm dowels

5

  6 dowels ø 5 mm 

6

   4 hexagonal socket head bolt M6 including  

4 nuts and 8 washers

7

  2 mounting clamps for wind gauge

8

  10 pcs AA battery

8. Definition of terms

Dew Point:

The dew point (Dew Point) refers to the point at which 
the air releases water vapour in the form of fog and / or 
condensate.

Example: 

if the air is cooled down constantly and 

the air humidity stays the same, the relative air hu-
midity increases to 100 %. This means that the dew 
point has been reached and the cooled air contains 
the maximum possible water vapour at this temperature.

Heat Index:

The heat index (Heat Index) is the air temperature 
felt on the human body taking into consideration 
the measured air temperature and the air humidity.

Wind Chill:

The wind chill (Wind Chill) refers to the difference  
between the measured (air temperature) and the 

Summary of Contents for 288624

Page 1: ...IAN 288624 PREMIUM WEATHER STATION PREMIUM WEATHER STATION Operation and Safety Notes...

Page 2: ...GB IE NI Operation and Safety Notes Page 3...

Page 3: ...Alarm function Page 15 16 Setting the air pressure unit Page 16 17 Air pressure adjustment Page 16 18 Setting the wind speed unit Page 16 19 Setting the wind alarm Page 16 20 Setting the wind chill a...

Page 4: ...al injury The word CAUTION warns of possible risks of minor injury or damage POINTS TO FURTHER INFORMATION 3 Intended use The weather station informs you of the current weather conditions and provides...

Page 5: ...that the product Premium weather station H13726 is in compliance with Directives 2014 53 EU 2011 65 EU and 2009 125 EC The full text of the EU declaration of conformity is avail able at the following...

Page 6: ...to the point at which the air releases water vapour in the form of fog and or condensate Example if the air is cooled down constantly and the air humidity stays the same the relative air hu midity in...

Page 7: ...nd speed temperature and humid ity to the weather station on 434MHz frequency Assembled on a mast of approx 25 31mm Can only be assembled in areas free from buildings walls or other obstructions as th...

Page 8: ...p outdoors The wind must be able to access the wind gauge from all sides to enable the wind force and wind direction to be measured accurately Ensure that the vane and the wind wheel are not blocked t...

Page 9: ...drill holes using the rain gauge before drilling the holes 5mm ensure that no elec trical cables or water pipes can be damaged 2 Push the supplied dowel into the drilled hole until it is flush with t...

Page 10: ...he housing carefully off the base of the product To open the battery compartment loosen the 4 cross head screws on the battery compart ment cover Lift off the battery compartment cover Insert the batt...

Page 11: ...ween temper ature felt by humans Heat Index and dew point Dew Point Button Press once Press for ap prox 3 sec CLOCK Switch display between local time date and day of the week Set date and time ALARM D...

Page 12: ...ind gauge and rain gauge and registering on the weather station 13 1 Calibrating the wind gauge The wind gauge must be recalibrated when using it for the first time as well as every time the battery i...

Page 13: ...is confirmed with a confirmation tone The measurement value dis plays now flash on the wind gauge and rain gauge displays The process can take up to 4 minutes 14 Weather station basic settings 14 1 Se...

Page 14: ...continuously on the display after approx 3 5 minutes Press again to deactivate the DCF 77 synchroni sation WARNING The displays for time and date in Central Europe are transferred via DCF 77 radio si...

Page 15: ...nia Monaco The Neth erlands Norway Austria Poland San Marino Sweden Switzerland Serbia Slovakia Slovenia Spain with the exception of the Canary Islands Czech Republic Hungary Set 1 Hr Bulgaria Estonia...

Page 16: ...in inches 17 Air pressure adjustment When batteries have been inserted in the weather station an air pressure of 1013hPa appears on the display This value is pre set You can adjust the air pressure t...

Page 17: ...on until ALARM appears next to the Wind Chill temperature Hold the WIND ALARM button down for approx 3 seconds until a confirmation tone sounds and the value flashes Use or to set the desired value Pr...

Page 18: ...tches off automatically 24 1 Date and time Press the CLOCK button to switch between the time date and day of the week If no button has been pressed for a period of approximately 20 seconds the time di...

Page 19: ...history Example Press the RAIN CLEAR until the rainfall quantity is shown The value shown represents the rainfall quantity for the current day Underneath this value a diagram is shown containing the r...

Page 20: ...d maximum values Use the MEMORY button to display saved minimum and maximum values 24 11 Weather forecast The weather station can predict the weather for the next 12 24 hours The weather prediction fu...

Page 21: ...o the main unit Inserting the rain gauge battery the lever at the middle position when pairing to the main unit Then the rain gauge enters the test mode Lever at the middle position Lever at the left...

Page 22: ...le dispose of it separately for better waste treatment The Triman logo is valid in France only Contact your local refuse disposal au thority for more details of how to dispose of your worn out product...

Page 23: ...IAN 288624 OWIM GmbH Co KG Stiftsbergstra e 1 DE 74167 Neckarsulm GERMANY Model No H13726 Version 07 2017 Last Information Update 08 2017 Ident No H13726082017 IE NI...

Reviews: