Lidén Weighing LUW2001/LBW User Manual Download Page 11

 

10 

                                                          7_O_1      ----    7-pit even parity check 

                                                          8_E_1      ----    8-pit odd parity check 

8_O_1      ----    8-pit even parity check 

F4.1.3    Baud Rate 

                                            Selectable  Parameters:  1200,  2400,  4800,  9600  (default 
value) 

F4.1.4 Continuous Output & Delivery Parity Check and Character (only for 

F4.1=3)   

                                    Selectable Parameters: 0 ---- no delivery (default value) 

1 ---- delivery 

F4.1.5    Bluetooth  Node  Setting  (effective  only  when  Bluetooth 

module option is configured) 

                                            Selectable  Parameters:  HoLi01~HoLi99  (default  value: 
HoLi01) 

F4.2    Parameter Setting of UART1 Printing Interface 

  F4.2.1    Whether to connect the printer 

                                  Selectable Parameters: 0 ---- not connected to the miniprinter 

(default) 

1 ---- connected to the miniprinter 

F4.2.2    Printing Carriage Return Character   

                                          Selectable  Parameters:  0~9  carriage  return  characters 
(default value: 3) 

F4.2.3    Printing Setting of Accumulative Scale   

Selectable  Parameters:  0  ----  total  accumulative  data  for 

printing (default value) 

1  ----  printing  detail  +  total 

accumulative data 

 

F5    Maintenance and Service 

       

F5.1    Key test 

                                Instrument display 

, press

Print

Zero

Tare

,   

Gross

lb/kg

  and 

Total

  in order, and the instrument 

displays 

 

Summary of Contents for LUW2001/LBW

Page 1: ...User manual for LUW2001 LBW...

Page 2: ...epair controller Warning Please keep good grounding of controller Warning In electrical connection of controller please cut off the power supply in advance Wait for 30 seconds between power on of the...

Page 3: ...METER SETTING 6 SETTING ENTRY 6 PARAMETER SETTING OF F1 SCALE 6 F2 APPLICATION FUNCTION SETTING 8 F3 ENERGY SAVING PARAMETER SETTING 9 F4 SERIAL PORT SETTING 9 F5 MAINTENANCE AND SERVICE 10 VI FUNCTIO...

Page 4: ...t 0 1A Frequency 50 60Hz 2 RS232 ports Operating temperature 10 40 relative humidity is below 85 Storage temperature 20 60 relative humidity is below 85 Conforming to standard GB T 7724 1999 II Main F...

Page 5: ...he lamp is off Zero center indication The lamp is on when the absolute value of weight on the scale is less than 0 2d otherwise the lamp is off Net Identification of gorses weight and net weight The l...

Page 6: ...rn to the last m en u Accumulation key Short key F2 1 4 include display weight in accumulation value Long key F2 1 3 select scale to sample target weight F2 1 4 accumulate weight of scale display F2 1...

Page 7: ...Hold button on the operating panel in the state of normal weighing If F1 14 0 you can set all the parameters within F1 F5 If F1 14 1 you can only set all parameters within F2 F5 If F1 14 1 and you ne...

Page 8: ...ighing platform to ensure that 10 of full scale value weight of weights full scale value and then press the Print key to start the next step Entering the same weight value as that of the loaded weight...

Page 9: ...2 Application Function Setting F2 1 Function Selection Selectable Parameters 0 Close the application functions default value 1 Weight keeping function 2 Percentage display function 3 Weight checking a...

Page 10: ...ers 0 250 minutes default value 150 minutes If set to be 0 this function shall not be allowed F3 3 Display Brightness Control Selectable Parameters 0 low light level 1 middle light level default value...

Page 11: ...99 default value HoLi01 F4 2 Parameter Setting of UART1 Printing Interface F4 2 1 Whether to connect the printer Selectable Parameters 0 not connected to the miniprinter default 1 connected to the min...

Page 12: ...ld indication lamp is on Only when weight setting value F2 2 is displayed weight maintenance operation is effective Otherwise it will return to weighing state after invalid operation information is sh...

Page 13: ...Total on operation panel if the display shows progress bar it indicates that the current display weight is included accumulated value and then it returns to normal weighing state If the display shows...

Page 14: ...2 1 6 Operation method In normal weighing state place the animal on the weighing platform and its weight must be threshold value set in F2 2 Press Total instrument will collect data sampling After sam...

Page 15: ...struments of the factory 7 The calibration input weight is too small Input 10 weight of full range 8 The weight in calibration is too light Load 10 weight of full range 9 The scale is dynamic in scale...

Page 16: ...s word A B C 3 Display weight possibly gross weight or net weight 6 digits without symbol or decimal point 4 Tare weight 6 digits without symbol or decimal point 5 CR ASCII carriage return ODH 6 CKS o...

Page 17: ...1 Constant 0 Bit 2 Constant 0 Bit 3 Constant 0 Bit 4 Constant 1 Bit 5 Constant 1 Bit 6 Constant 0 Bit 7 Constant 0 check bit 2 Continuous output A format The data transmitted by continuous output prot...

Page 18: ...the scale is in stable state US the scale is in unstable state HEAD2 GS gross weight NT net weight DATA instrument display data UNIT kg or lb CR LF new line Example 1 in stale state gross weight is 18...

Page 19: ...weight Print details and total weight Only print total weight F2 1 5 counting scale press Print REPORT Gross 1 980kg State Less REPORT Gross 2 000kg State OK REPORT Gross 2 020kg State Over REPORT Gr...

Reviews: