Liberty Pumps SBX Series Installation Manual Download Page 8

 

©Copyright 2012 Liberty Pumps Inc.    All rights reserved                                                             8 

 

 

 

 

 

 

 

 

 

 

 

 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

 Liberty Pumps, Inc. assumes no responsibility for damage or injury due to disassembly in the field.  Disassembly, other than at 

Liberty Pumps or its authorized service centers, automatically voids warranty. 

 

 

3 Year Limited Warranty

  

Liberty Pumps, Inc. warrants that pumps of its manufacture are free from all factory defects in material 

and workmanship for a period of 3 years from the date of purchase.  The date of purchase shall be determined by a dated sales receipt 

noting the model and serial number of the pump.  The dated sales receipt must accompany the returned pump if the date of return is 

more than 3 years from the "CODE" (date of manufacture) number noted on the pump nameplate.  The manufacturer's obligation under 

this Warranty shall be limited to the repair or replacement of any parts found by the manufacturer to be defective,  provided the part or 

assembly  is  returned  freight  prepaid  to  the  manufacturer  or  its  authorized  service  center,    and  provided  that  none  of  the  following 

warranty-voiding  characteristics  are  evident:    The  manufacturer  shall  not  be  liable  under  this Warranty  if  the  product  has  not  been 

properly  installed;    if  it  has  been  disassembled,  modified,  abused  or  tampered  with;    if  the  electrical  cord  has  been  damaged  or 

improperly spliced;  if the pump discharge has been reduced in size;  if the pump has been used in water above the rated temperature, 

or water containing sand, lime, cement, gravel or other abrasives; if the product has been used to pump chemicals or hydrocarbons;  if 

a  non-submersible  motor  has  been  subjected  to  excessive  moisture;  or  if  the  label  bearing  the  serial  and  code  number  has  been 

removed.  Liberty Pumps, Inc. shall not be liable for any loss, damage or expenses resulting from installation or use of its products, or 

for  consequential  damages,  including  costs  of  removal,  reinstallation  or  transportation.   

There  is  no  other  express warranty.    All 

implied warranties, including those of merchantability and fitness for a particular purpose, are limited to three years from the 

date of purchase.  

This Warranty contains the exclusive remedy of the purchaser, and, where permitted, liability for consequential or 

incidental damages under any and all warranties are excluded.

 

 

 

 

Pump will not turn 

off. 

 

Switch(s) unable to move to the 

“turn off” position due to 

interference with the side of basin 

or other obstacle. 

 

Position the pump or switch so that it has 

adequate clearance for free operation. 

 

Defective switch. 

 

Remove and replace switch. 

Pump runs or hums, 

but does not pump. 

 

Discharge is blocked or restricted. 

 

Check the discharge line for foreign material, 

including ice if the discharge line passes 

through or into cold areas. 

 

Check valve is stuck closed or 

installed backwards. 

 

Remove check valve(s) and examine for 

freedom of operation and proper installation. 

 

Gate or ball valve is closed. 

 

Open gate or ball valve. 

 

Total lift is beyond pump's 

capability. 

 

Try to route piping to a lower level.  If not 

possible, a larger pump may be required.  

Consult the factory.

 

Pump runs or hums 

but does not pump 

 

Pump impeller is jammed or volute 

casing is plugged. 

 

Remove the pump from the basin.  Detach the 

pump base and clean the area around the 

impeller.  Reassemble and reinstall. 

Pump runs 

periodically when 

fixtures are not in 

use. 

 

Check valve was not installed, is 

stuck open or is leaking. 

 

Remove check valve(s) and examine for 

freedom of operation and proper installation. 

 

Fixtures are leaking. 

 

Repair fixtures as required to eliminate leakage. 

Pump operates 

noisily. 

 

Foreign objects in the impeller 

cavity. 

 

Remove the pump from the basin.  Detach the 

pump base and clean the area around the 

impeller.  Reassemble and reinstall. 

 

Broken impeller. 

 

Consult the factory for information regarding 

replacement of impeller. 

 

Worn bearings. 

 

Return pump to the factory or authorized repair 

station for repair. 

 

Piping attachments to building are 

too rigid. 

 

Replace a portion of the discharge line with 

rubber hose or connector. 

Summary of Contents for SBX Series

Page 1: ...e Tree Avenue Bergen NY 14416 Phone 800 543 2550 Fax 585 494 1839 www libertypumps com Contents 1 General Information 2 Precautions Pre installation 3 Installation 4 Operation and Maintenance 5 Troubl...

Page 2: ...and amperage requirements of the motor as noted on the pump nameplate The electrical outlet or panel shall be within the length limitations of the pump power cord and at least 4 feet above floor level...

Page 3: ...per ground has been established A UL listed circuit analyzer will indicate if the power neutral and ground wire are properly connected 8 A qualified licensed electrician should install and test all el...

Page 4: ...with applicable codes A Remove and recycle the disposable protective cover before plumbing the system B NOTE Threaded connections at cover HAND TIGHTEN ONLY and use Teflon tape as a thread sealant Rem...

Page 5: ...rovided on the cover to properly center the drill see figure 4 above Install the provided 3 pipe seal in the hole Place 3 PVC vent pipe from the vent system through the pipe seal Do not place the vent...

Page 6: ...cover Lift up on the two handles see fig 8 and remove the strainer basket Caution water will continue to drip from strainer after removal Clean the basket by dumping the debris and rinsing Reinstall...

Page 7: ...ing for proper connections and adequate voltage and capacity Switch is unable to move to the turn on position due to interference with the side of basin or other obstruction Position the pump or switc...

Page 8: ...n or transportation There is no other express warranty All implied warranties including those of merchantability and fitness for a particular purpose are limited to three years from the date of purcha...

Page 9: ...P 115V SBX280A 1 2HP 115V Alarma ALM 2 IMPORTANTE cuando est instalando la unidad aseg rese de dejar suficiente espacio para acceder a las cubiertas del sistema y poder prestar servicio al tamiz inter...

Page 10: ...metros 4 pies como m nimo por encima del piso para evitar problemas en caso de inundaci n Se deber instalar la unidad seg n las disposiciones del c digo el ctrico nacional NEC de Estados Unidos y tod...

Page 11: ...nes del NEC 7 Compruebe que todos los tomacorrientes est n conectados a tierra Se puede usar un analizador de circuitos con aprobaci n UL para verificar que la energ a el neutro y el hilo de masa est...

Page 12: ...as de residuos y de ventilaci n deben ser instaladas por un profesional calificado y conforme a los c digos aplicables A Quite la tapa desechable de protecci n y rec clela antes de empezar a montar la...

Page 13: ...para que la junta obturadora no permita el paso de gases vea la figura 5 Las juntas obturadoras deben crear un sello entre las tapas B Instale una l nea de ventilaci n de 7 62 cm 3 plg en el punto de...

Page 14: ...o Agarre las dos asas figura 8 y saque el tamiz Tenga cuidado ya que seguir goteando agua del tamiz cuando lo haya retirado Vac e la suciedad que haya en el tamiz y enju guelo Vuelva a instalarlo tan...

Page 15: ...le o el flujo el ctrico se ha visto interrumpido de alg n otro modo tensi n incorrecta Compruebe que la bomba est enchufada Haga que un electricista compruebe que todos los cables est n correctamente...

Page 16: ...citas incluidas las de comerciabilidad y adecuaci n para un prop sito determinado est n limitadas a un plazo de tres a os a partir de la fecha de compra Esta garant a representa el nico remedio del co...

Page 17: ...0 1 2 HP 115 V SBX280A 1 2HP 115 V ALM 2 Alarme IMPORTANT Afin de permettre l entretien du filtre de l interrupteur et de la pompe s assurer de permettre un acc s facile aux couvercles protecteurs du...

Page 18: ...e de la pompe La prise lectrique ou le panneau doit se trouver la port e du cordon d alimentation de la pompe et au moins 1 2 m 4 pi au dessus du niveau du plancher pour minimiser les dangers possible...

Page 19: ...rer que la mise la terre fonctionne bien Un multim tre approuv par UL indiquera si les fils sous tension neutres et de mise la terre sont raccord s correctement 8 Un lectricien autoris qualifi doit in...

Page 20: ...igueur A Retirer et recycler le couvercle de protection jetable avant de raccorder la plomberie du syst me B REMARQUE Raccordements filet s au couvercle RESSERRER LA MAIN SEULEMENT et utiliser du ruba...

Page 21: ...Installer l anneau d tanch it de 3 po pour tuyau dans l orifice Installer un tuyau d vent de 3 po dans l orifice de ventilation travers l anneau d tanch it pour tuyau Ne pas ins rer le tuyau d vent pl...

Page 22: ...t retirer le couvercle d acc s Soulever le deux poign es voir fig 8 et retirer le panier filtrant Mise en garde de l eau va continuer d goutter du panier apr s son retrait Nettoyer le panier en jetant...

Page 23: ...uer des r glages Probl me Cause Mesure correctrice La pompe ne fonctionne pas Fusible br l ou autre interruption d alimentation tension inad quate S assurer que le branchement de l appareil est s curi...

Page 24: ...it marchande et d aptitude une fin particuli re est limit e trois ans partir de la date d achat Cette garantie contient le recours exclusif de l acheteur et exclut lorsque permis par la loi toute resp...