Risk of electric shock.

  Always disconnect the pump from the power source before handling or making adjustments.   

 

This pump is supplied with a grounding conductor and grounding-type attachment plug.  To reduce the risk of electric shock, be 
certain that it is connected only to a properly grounded, grounding-type receptacle.  This receptacle should be protected by a 
ground fault circuit interrupter (GFCI 

 

Never remove the ground pin from the plug. 

 

Do not use an extension cord. 

 

 

 

 

All electrical circuitry should be installed by qualified personnel in accordance with the National Electric Code (NEC) and all 
applicable local codes or ordinances. 

 

This pump requires separate, properly fused and grounded branch circuit.  Make sure the power source is properly sized for the 
voltage and amperage requirements of the motor, as noted on the pump nameplate. 

 

The electrical outlet or panel shall be within the length limitations of the pump power cord, and at least 4 feet above floor level to 
minimize possible hazards from flood conditions.   

 

Fig. 2 – Direct Wiring of 115V or 208-230V,  

Single Phase, Automatic Pumps 

If the pump is to be wired directly into a control device or junction box, 
and it is necessary to remove the plugs, have a certified electrician do 
the wiring in accordance with the National Electric Code and applicable 
local codes.  See Fig. 2 for direct wire installation of single phase 
automatic pumps. 

 

 

 

 
 
 
 

3. Maintenance and Troubleshooting 

Risk of electric shock.

  Always disconnect the pump from the power source before handling or making 

adjustments.   
 

 
 

 

Problem 

Cause 

Correction 

 

Blown fuse or other interruption of 
power; improper voltage. 

 

Check that the unit is securely plugged in.  
Have an electrician check all wiring for proper 
connections and adequate voltage and 
capacity. 

 

Switch is unable to move to the 
“turn on” position due to 
interference with the side of basin 
or other obstruction 

 

Position the pump or switch so that it has 
adequate clearance for free operation. 

 
 
 

 

 

Insufficient liquid level. 

 

Make sure the liquid level is allowed to rise 
enough to activate switch(s). 

 

Pump will not run. 

 

Defective switch. 

 

Remove and replace switch. 

 

Switch(s) unable to move to the 
“turn off” position due to 
interference with the side of basin 
or other obstacle. 

 

Position the pump or switch so that it has 
adequate clearance for free operation. 

Pump will not turn 
off. 

 

Defective switch. 

 

Remove and replace switch. 