ColorSave 1000ST-INJ user manual
29
4.5.5 “No Rotation” Alarm
This alarm appears when the controller has sent a signal to the motor to rotate,
but the motor does not rotate.
There are three possible reasons for this failure:
1.
Motor driver problem
2.
Motor problem
3.
Motor cable problem
Press OK button to return to Main Screen
4.5.6 “Out Of Tolerance” Alarm
When the parameter Permitted Tolerance set to On, this alarm appears when
the actual percentage is smaller than the desired percentage in a percentage
that is bigger than the value of the permitted tolerance value. See section 4.3.7
Setting permitted tolerance for more information.
Press OK button to return to Main Screen
4.5.7 Alarm Output (J2)
Once one of the alarm situations occurs (except for "Feed Deviation" alarm), Alarm Output is
activated. Pins 1 and 4 – dry contact closed. Pins 2 and 3 – 24VDC active 30mA max.
It will remain active for as long as the alarm situation continues (except for Feed Deviation).
4.5.8 Alarm List
The Alarm List screen shows the list of alarms that
are currently active.
You can enter the Alarm List screen anytime by
pressing the red frame in the top left area in the main
screen.
Press Log button in order to see Alarm Log screen
(see section
Press Back button to return to the previous screen.
4.5.9 Alarm Log
The Alarm Log screen shows the log of the alarms of
the ColorSave 1000ST-INJ. Each alarm is shown next
to the date and time of the alarm raise.
Press Prev button to scroll to the previous log screen.
Press Next button to scroll to the next log screen.
Press Back button to return to the previous screen.
Note: The alarm log remains even after shutting
down and starting up the ColorSave 1000ST-INJ.