15
ADVANCED FUNCTIONS
ENGLISH
ON/OFF
button
Restarting the air conditioner
automatically
When the air conditioner is turned on again
after a power failure, this function restores
the previous settings. This function is a fac-
tory default setting.
1
Open the front grille.
- Lift up both sides of the cover slightly.
2
Press the On/Off button and hold it for 6
seconds.
- The unit will beep twice and the lamp will
blink twice 4 times.
- To re-enable the function, press the On/
Off button and hold it for 6 seconds. The
unit will beep twice and the blue lamp
will blink 4 times.
* The feature can be changed according a
type of model.
ON/OFF
button
Disabling auto restart
NOTE
!
If you press and hold the On/Off button
for 3 – 5 seconds instead of 6 seconds,
the unit will switch to the test operation.
In the test operation, the unit blows out
strong air for cooling for 18 minutes and
then returns to the factory default set-
tings.
Operating the air conditioner
without the remote control
You can use the On/Off button of the indoor
unit to operate the air conditioner when the
remote control is unavailable. However, the
fan speed is set to high.
1
Open the front grille.
- Lift up both sides of the cover slightly.
2
Press the On/Off button.
- For cooling and heating models, the oper-
ation mode changes, depending on the
room temperature.
* The feature can be changed according a
type of model.
- For cooling-only models, the temperature
is set to 22°C (71.6°F).
Room temp.
Set temp.
Operation
mode
Above 21°C
and below
24°C
23°C
Dehumidify-
ing operation
Above 24°C
22°C
Cooling
operation
Summary of Contents for ZSNQ186C7A0