background image

15

ADVANCED FUNCTIONS

ENGLISH

ON/OFF

button

Restarting the air conditioner
automatically

When the air conditioner is turned on again
after a power failure, this function restores
the previous settings. This function is a fac-
tory default setting.

1

Open the front grille.

- Lift up both sides of the cover slightly.

2

Press the On/Off button and hold it for 6
seconds.

- The unit will beep twice and the lamp will

blink twice 4 times. 

- To re-enable the function, press the On/

Off button and hold it for 6 seconds. The
unit will beep twice and the blue lamp
will blink 4 times.

* The feature can be changed according a

type of model.

ON/OFF

button

Disabling auto restart

NOTE

!

If you press and hold the On/Off button
for 3 – 5 seconds instead of 6 seconds,
the unit will switch to the test operation.
In the test operation, the unit blows out
strong air for cooling for 18 minutes and
then returns to the factory default set-
tings.

Operating the air conditioner
without the remote control

You can use the On/Off button of the indoor
unit to operate the air conditioner when the
remote control is unavailable. However, the
fan speed is set to high.

1

Open the front grille.

- Lift up both sides of the cover slightly.

2

Press the On/Off button.

- For cooling and heating models, the oper-

ation mode changes, depending on the
room temperature.

* The feature can be changed according a

type of model.

- For cooling-only models, the temperature

is set to 22°C (71.6°F).

Room temp.

Set temp.

Operation

mode

Above 21°C
and below
24°C

23°C

Dehumidify-
ing operation

Above 24°C

22°C

Cooling 
operation

Summary of Contents for ZSNQ186C7A0

Page 1: ...R S MANUAL Please read this manual carefully before operating your set and retain it for future reference TYPE WALL MOUNTED INVERTER MODELS Indoor Unit Outdoor Unit ZSNQ186C7A0 ZSUQ186C7A0 AIR CONDITIONER www lg com ENGLISH ...

Page 2: ...irection of the air flow vertically or horizontally to circulate indoor air Speed up the fan to cool or warm indoor air quickly in a short period of time Open windows regularly for ventilation as the indoor air quality may deteriorate if the air con ditioner is used for many hours Clean the air filter once every 2 weeks Dust and impurities collected in the air filter may block the air flow or weak...

Page 3: ...esult in serious injury or product failure Always use a power plug and socket with a ground terminal Failure to do so may result in electric shock or product failure Install the panel and the cover of the control box safely Failure to do so may result in explo sion or fire Install a dedicated electric outlet and circuit breaker before you use the air conditioner Failure to do so may result in elec...

Page 4: ...conditioner is submerged into water due to flood ing Failure to do so may result in explosion or fire Be cautious water could not enter the product Make sure to ventilate sufficiently when this air conditioner and a heating appliance such as a heater are used simultaneously Failure to do so may result in fire serious injury or product failure Turn the main power off and unplug the power plug when ...

Page 5: ...esult in se rious injury or product failure Do not place any objects on the air conditioner It may result in product failure Always insert the filter securely after cleaning Clean the filter every two weeks or more often if necessary Do not insert hands or other objects through the air inlet or outlet while the air conditioner is operat ing It may result in electric shock Do not drink the water dr...

Page 6: ...t ically at a set time 12 Turning off the air conditioner auto matically at a set time 12 Canceling the timer setting 12 Setting sleep mode 13 ADVANCED FUNCTIONS 13 Changing room temperature quickly 13 Indoor air purification 14 Auto operation 14 Energy saving cooling mode 14 Display screen brightness 15 Operating the air conditioner without the remote control 15 Restarting the air conditioner aut...

Page 7: ... of operation lamps and their locations may vary depending on the model of the air conditioner The feature can be changed according a type of model NOTE The feature can be changed according a type of model 7 BEFORE USE ENGLISH Indoor unit Operation ranges The table below indicates the temperature ranges the air conditioner can be operated within Mode Indoor temperature outdoor temperature Cooling ...

Page 8: ...er on off f A C Operation mode selection button Se lects the operation mode Cooling operation A Auto operation or Auto changeover C o Temperature adjustment button Adjusts the room temperature when cooling A m Jet cooling Warms up or coo ls down the indoor temperature within a short period of time g L Indoor Fan speed button Adjusts the fan speed D I Air flow direction button Adjusts the air flow ...

Page 9: ...the holder before at taching it to the wall 3 Fix the holder by fastening the 2 screws firmly with a screwdriver 4 Slide the remote control into the holder Point the remote control towards the signal receiver at the bottom of the air conditioner to operate it NOTE If the display screen of the remote con trol starts to fade replace the batteries The feature can be changed according a type of model ...

Page 10: ...y season in order to prevent mold from setting in This mode adjusts the room temperature and the fan speed automatically to maintain the optimal level of humidity 1 Press to turn on the power 2 Press repeatedly to select the dehu midifying operation D is displayed on the display screen NOTE You can use this fuction by pressing without turning the air conditioner on In this mode you cannot adjust t...

Page 11: ...tion Select I to adjust the direction of the air flow automatically Setting the timer You can use the timer function to save energy and to use the air conditioner more efficiently Setting the current time 1 Press p and hold it for longer than 3 sec onds The AM PM icon flickers at the bottom of the display screen 2 Press E or F to select the minutes 3 Press p to finish NOTE Adjusting the air flow d...

Page 12: ...r settings press p Setting sleep mode Use the sleep mode to turn off the air condi tioner automatically when you go to sleep 1 Press to turn on the power 2 Press l 3 Press E or F to select the hour up to 7 hours 4 Press p to finish T is displayed on the display screen in sleep mode NOTE In the Cooling and Dehumidifying modes the temperature increases by 1 C 1 8 F after 30 minutes and by a further ...

Page 13: ...isture is generated inside the indoor unit Use the auto cleaning function to remove such moisture 1 Press to turn on the power 2 Press F J is displayed on the display screen If you turn off the power the fan oper ates for 30 minutes and cleans the inside of the indoor unit NOTE Powerful Cooling Cooling Only Model Enable in Cooling Dehumidifying Fan Artficial Intelligent Air Clean Operation This fu...

Page 14: ...ing on the model Display screen brightness You can adjust the brightness of the indoor unit display screen Press to turn on off thedisplay screen Energy saving cooling mode This mode minimizes power consumption dur ing cooling and increases the set temperature to the optimal level for a more comfortable en vironment 1 Press to turn the power on 2 Press f repeatedly to select the cooling operation ...

Page 15: ...and hold the On Off button for 3 5 seconds instead of 6 seconds the unit will switch to the test operation In the test operation the unit blows out strong air for cooling for 18 minutes and then returns to the factory default set tings Operating the air conditioner without the remote control You can use the On Off button of the indoor unit to operate the air conditioner when the remote control is ...

Page 16: ...an Air filter CAUTION Turn off the power and unplug the power cord before you perform any maintenance other wise it may cause electric shock Never use water that is hotter than 40 C when you clean the filters It may cause deforma tion or discoloration Never use volatile substances when you clean the filters They may damage the surface of the product NOTE The location and shape of the filters may d...

Page 17: ...Hold the knob of the air filter lift it up slightly and remove it from the unit 4 Clean the filter with a vacuum cleaner or with warm water If dirt is difficult to remove wash the fil ter in lukewarm water with detergent 5 Dry the filter in the shade NOTE The location of the filters may differ de pending on the model The plasma filter may not be included in some models The feature can be changed a...

Page 18: ...r Water leaks from the indoor unit even when the humidity level is low The power cord is damaged or generating excessive heat A switch a circuit breaker safety ground or a fuse is not operated properly The air conditioner does not work The air conditioner is unplugged Check whether the power cord is plugged into the outlet A fuse is blown or the power supply is blocked Replace the fuse or check if...

Page 19: ... the current temperature There is a heating source nearby Avoid using a heat generator such as an electric oven or a gas burner while the air conditioner is in operation Air circulation opera tion is selected In the air circulation operation air blows from the air conditioner without cooling or heating the indoor air Switch the opera tion mode to the cooling operation It is not possible to adjust ...

Page 20: ...20 ENGLISH ...

Page 21: ...lifesgoodpage LGIndiaTweets Call 1800 180 9999 SMS 5757554 www lg com serviceindia lge com LG Electronics India Pvt Ltd Registered Office A Wing 3rd Floor D 3 District Center Saket New Delhi 110017 ...