35
Leads
Drain Hose-p
Pump fixing screw
4) Disassembly of Back cover, Drain
Pump.
Remove back cover fixing screws then disassemble
the back cover.
Disconnect the leads and the drain hose-p from the
drain pump.
Remove the pump fixing screws and the connector
hose to disassemble the drain pump.
5) Replacement of Damper asm
Separate top cover from washing machine.
As in the fig, lift snubber bar and take it out of out
case with out tub.
Damper assembly shall not be disassembled.
Replace damper as assembly.
For assembly, keep the following.(Location & color)
Location
P/No.
PIVOT(Color)