POWER SUPPLY
COOLING CAPACITY
INPUT
RUNNING CURRENT
REFRIGERANT (R-22) CHARGE(g)
OPERATING
INDOOR(°C)
TEMPERATURE
OUTDOOR(°C)
EVAPORATOR
CONDENSER
FAN, INDOOR
FAN, OUTDOOR
FAN SPEEDS, FAN/COOLING
FAN MOTOR
OPERATION CONTROL
ROOM TEMP. CONTROL
AIR DIRECTION CONTROL
CONSTRUCTION
PROTECTOR
COMPRESSOR
FAN MOTOR
POWER CORD
DRAIN SYSTEM
NET WEIGHT
(lbs/kg)
OUTSIDE DIMENSION
(inch)
(W x H x D)
(mm)
MODELS
ITEMS
RAD-183A
Table -1
1Ø, 208/230V, 60Hz
17,500/18,000
1,800/1,850
9.7
720g(25.4oz)
27(DB),19(WB)
35(DB),24(WB)
2 ROW 15 STACKS
LOUVERED-FIN TYP
2 ROW 19 STACKS,LOUVERED-FIN TYPE
TURBO
PROPELLER TYPE FAN WITH SLINGER-RING
3/3
6 POLES
WIRELESS REMOCN
THERMISTOR
VERTICAL LOUVER(RIGHT & LEFT)
HORIZONTAL LOUVER(UP & DOWN)
SLIDE IN-OUT CHASSIS
INTERNAL OVERLOAD PROTECTOR
INTERNAL THERMAL PROTECTOR
3 WIRE WITH GROUNDING
CORD-CONNECTED TYPE(ATTATCHMENT PLUG:OPTION)
DRAIN PIPE OR SPLASHED BY FAN SLINGER
130/60
26 x 16 27/32 x 26 9/16
660 x 428 x 675