background image

*MFL70643110*

MFL70643110

Rev.00_010521

www.lg.com

Copyright ©  2021 LG Electronics Inc. All Rights Reserved.

 

OWNER’S MANUAL

AIR 

CONDITIONER

TYPE : WINDOW

EN 

ENGLISH

Read this owner's manual thoroughly before operating the

appliance and keep it handy for reference at all times.

W051CE  SSP

Summary of Contents for W051CE SSP

Page 1: ...www lg com Copyright 2021 LG Electronics Inc All Rights Reserved OWNER S MANUAL AIR CONDITIONER TYPE WINDOW EN ENGLISH Read this owner s manual thoroughly before operating the appliance and keep it handy for reference at all times W051CE SSP ...

Page 2: ... 8 Circuit Breaker Installation 11 OPERATION 11 Control Panel and Remote Control 12 Wireless Remote Control 13 Air Direction 13 Slinger Fan 8 Installation Overview 9 Unit Installation 9 How to Install the Unit 9 Space for Outside Air Flow 10 Drain Pipe 14 MAINTENANCE 14 Air Filter 15 TROUBLESHOOTING 15 Before Calling for Service 15 Normal Sounds You May Hear ...

Page 3: ...cause damage to the product if you do not follow instructions All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what may happen if the instructions are not followed IMPORTANT SAFETY INSTRUCTIONS WARNING injury to persons when using this product follow basic precautions including the following INSTALLATION Before use the applianc...

Page 4: ...cking and installing The edges of the product may be sharp Disconnect the power cord or circuit breaker before installing or servicing the appliance Keep packaging materials out of the reach of children These materials can pose a suffocation risk to children Store and install the product where it will not be exposed to temperatures below freezing or exposed to outdoor weather conditions other appl...

Page 5: ...rosion or damage EN GROUNDING INSTRUCTIONS The power cord of this appliance is equipped with a three prong grounding plug Use this with a standard three slot grounding wall power outlet to minimize the hazard of electric shock The sure the receptacle is properly grounded DO NOT CUT OR REMOVE THE THIRD GROUND PRONG FROM THE POWER PLUG Attaching the adapter ground terminal to the wall receptacle cov...

Page 6: ...ppliance Do not use waxes thinners or harsh detergents Do not step on or place heavy objects on top of the appliance Do not drink water drained from the appliance are used simultaneously Remove the batteries if the remote control is not to be used for an extended period of time Never mix different types of batteries or old and new batteries for the remote control consult a doctor Do not recharge o...

Page 7: ... Parts Interior Parts 1 Evaporator 2 Air Guide 3 4 Compressor 5 6 Condenser Base Pan Power Cord 3 4 5 2 1 6 1 Control Panel 2 Remote Control 3 Air Filter 4 5 Cabinet 6 7 Front Grille Air Outlet Horizontal Air Deflector Vertical Louver 5 4 7 1 3 2 6 ...

Page 8: ...llation Overview Tools Needed Phillips head screwdriver Flat blade screwdriver Level Pencil Tape measure Cutting knife Scissors Read thoroughly and follow all directions provided A circuit breaker must be installed between the power source and the unit if the plug is not used see illustration below NOTE Use 15 A circuit breaker INSTALLATION ...

Page 9: ...llow condensed water to drain About 10 15 mm or 1 4 bubble with Level 4 The unit should be installed with a slight tilt Fence Awning Heat radiation Cooled air CAUTION The external grille must be exposed outside for air discharge 10 15 mm Over 50 cm Foam 70 150 cm Level 1 4 Bubble 100 mm minimum AIR IN AIR IN AIR OUT OPTION A 100 mm 100 mm LOUVRE FRONT 45 BRICK CUT AWAY TO CLEAR LOUVRES 45 BRICK CU...

Page 10: ...ove the drain cap and secure the drain pipe to the rear hole of the base pan Press the drain pipe into the hole by pushing down and away from the fins to avoid injury CAUTION Be careful when inserting the drain pipe Push away from the sharp fin area to avoid slipping injuring yourself Hang Drain Cap Push Drain Pipe ...

Page 11: ...the fan circulates air but the compressor does not run Use the Fan Speed Nivel Vent button to set speed to High Medium or Low In this mode you cannot adjust the set temperature Dry Deshum This mode is ideal for rainy and damp days to dehumidify the room rather than cooling it significantly Humidity is removed from the room by the combination of compressor operation and the fan speed fixed at Low T...

Page 12: ... or decrease temperature setting 6 Remote Control Sensor Clean Filter The Clean Filter Limpieza Filtro LED lights up to notify you that the filter needs to be cleaned After cleaning the filter press Temp and together on the control panel to turn off the Clean Filter Limpieza Filtro light NOTE control panel not the remote control This feature is a reminder to clean the air light turns on after 250 ...

Page 13: ... gets high enough The water is then picked up by the fan and expelled through the condenser making the air conditioner more efficient Ring Air Direction Adjusting the air direction using the horizontal air deflector control Using the control tabs the air flow can be directed to the left right straight ahead or any combination of these directions 13 OPERATION EN ...

Page 14: ...mpened in a mild detergent solution Wash the cabinet with mild soap or detergent and lukewarm water then polish using liquid appliance wax NOTE condenser coils outside of unit should be To ensure continued peak efficiency the checked periodically and cleaned if clogged with soot or dirt from outside air For repair and maintenance contact a LG Electronics Customer Information Center Have your model...

Page 15: ...e front of the unit you may hear the sound of rushing air being moved by the fan Today s high efficiency compressors may have a high pitched chatter during the cooling cycle 3 Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation 4 Vibration Unit may vibrate and make noise because of poor wall or window construction or incorrect in...

Page 16: ...of the Power failure If power failure occurs turn the mode control to off When power is compressor overload The air filter is dirty Clean the filter at least every 2 weeks See the MAINTENANCE Cleaning the Air Filter section The cooling coils are iced over Ice may block the air flow and obstruct the air conditioner from properly cooling the room Set the Fan Speed High at Fan or Cool mode The temp c...

Page 17: ...he air conditioner slants slightly Moisture removed from air and drains into base pan This is normal for a short period in areas with little humidity normal for a longer period in very humid areas from the cabinet front to the rear Dirty air filter air restricted Clean air filter Noise when unit is Room too cold cooling Window vibration poor installation Refer to installation instructions or check...

Page 18: ......

Reviews: