- 115 -
VX9100
LGE Internal Use Only
Copyright © 2007 LG Electronics. Inc. All right reserved
Only for training and service purposes
Checking Flow
Checking Flow
¾
Setting: “ON” at the motor test of “test mode”
+3.0V_MOTOR Voltage = 3.0V?
Replace Vibrator
Not Good
Not Good
YES
Good
Good
NO
Start
The vibrator will Work properly
Change the Sub-PMIC U500
Check the FPCB
Resolder Vibrator
Conenction
Check the Vibrator’s Connection
Change the FPCB
YES