Forced operation
Operation procedures when the remote con-
trol can't be used. The operation will be
started if the ON/OFF button is pressed.
If you want to stop operation, re-press the
button.
* The feature can be changed according to
type of model.
- For cooling and heating models, the oper-
ation mode changes, depending on the
room temperature.
- For cooling-only models, the temperature
is set to 22°C.
Auto Restart Function
This function is useful in the situation of
power failure.
When power regains after a failure this fea-
ture restore the previous operating condition
and the air conditioner will run in the same
settings.
ADVANCED FUNCTIONS
15
ENGLISH
ON/OFF
button
Room temp.
Set temp.
Operation
mode
Below 21°C
24°C
Heating
operation
Above 21°C
And Below 24°C
23°C
Dehumidifying
operation
Above 24°C
22°C
Cooling
operation
NOTE
!
This feature is enabled by factory default
setting, but you can disable it by pressing
the ON/OFF button for 6 seconds. The
unit will beep twice and the indicator
lamp(2) will blink 4 times.
To enable it, press the button again for 6
seconds. The unit will beep twice and the
indicator lamp(1) will blink 4 times.
NOTE
!
Test operation
During the TEST OPERATION, the unit op-
erates in cooling mode at high speed fan,
regardless of room temperature and re-
sets in 18 minutes. During test operation,
if remote controller signal is received, the
unit operates as remote controller sets.
If you want to use this operation, Press
and hold the ON/OFF button for 3~5 sec-
onds, then the buzzer sound 1 "beep".
If you want to stop the operation, re-press
the button.