This device is to be serviced only by properly qualified service personnel.
Consult the service manual for proper service procedures to assure continued safety operation and for precautions to be
taken to avoid possible exposure to excessive microwave energy.
PRECAUTIONS TO BE OBSERVED BEFORE AND
DURING SERVICING TO AVOID POSSIBLE
EXPOSURE TO EXCESSIVE MICROWAVE ENERGY
A) Do not operate or allow the oven to be operated with the door open.
B) Make the following safety checks on all ovens to be serviced before activating the magnetron or other
microwave source, and make repairs as necessary; (1) interlock operation, (2) proper door closing, (3)
seal and sealing surfaces (arcing, wear, and other damage), (4) damage to or loosening of hinges and
latches, (5) evidence of dropping or abuse.
C) Before turning on microwave power for any service test or inspection within the microwave generating
compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment,
integrity, and connections.
D) Any defective or misadjusted components in the interlock, monitor, door seal, and microwave generation
and transmission systems shall be repaired, replaced, or adjusted by procedures described in this manual
before the oven is released to the owner.
E) A microwave leakage check to verify compliance with the Federal Performance Standard should be
performed on each oven prior to release to the owner.
SAFETY PRECAUTIONS
Summary of Contents for Sunbeam MA-6400B2
Page 25: ...6 2 13552A 13213A 13581A 13720D 14970A 14026A 13536A 13352A DOOR PARTS ...
Page 26: ...6 3 24781T 23572A 24510L 250201 24970A 249401 26549T CONTROLLER PARTS ...
Page 27: ...6 4 33390G 35889A WSZ185 33112U WTP013 36549S 33052A 948502 WTT010 OVEN CAVITY PARTS WTT020 ...
Page 28: ...6 5 466001 466003 WTT028 466001 43500A 56912B 55262A WSZ085 SUCTION GUIDE PARTS ...