17
ENGLISH
ADVANCED FUNCTIONS
The air conditioner offers some additional ad-
vanced functions.
Motion-eye sensor
State of the art human body sensor detects
the people indoors and sends cool air to fit the
activity and number of people inside the room.
1
Press
|
to turn on the power.
2
Press
U
during cool operation.
-
a
is displayed on the display screen.
- Every time
U
is pressed, it rotates in
the order of Direct wind
➔
Indirect wind
➔
General operation.
- Human detection sensor detects the IR
ray from the human body and identifies
the location and movement of the human
body.
- Air conditioner automatically adjusts the
wind level and direction based on the
human activity and number of people.
- Air conditioner sends the customized
wind to the people through side and pop-
up window and magic wing.
Direct wind
- Human sensor detects the activity and num-
ber of people and sends cool air in the direc-
tion of the people.
1
Press
U
to set the direct wind during
cool operation.
* Energy saving effect of direct wind
- Motion-eye sensor automatically controls the
wind level and direction as well as cooling
temperature based on the location and activ-
ity of the user, and can save up to 50% of
energy compared to the common air condi-
tioner.
Indirect wind
- Human sensor detects the activity and num-
ber of people and sends cool air near the per-
son so that it does not contact the body
directly.
1
Press
U
to set the direct wind during
cool operation.
ADVANCED FUNCTIONS
Reference
• This function can only be set in the cool
operation mode.
• This function does not operate in the dehu-
midifier operation, smart sleep, smart en-
ergy saving and air cleaner operation only.
• Sensitivity of the human body can vary by
the indoor environment.
• Depending on the installation or used envi-
ronment, heat emitting object such as
monitor can be recognized as human.
• Up/Down wind of pop-up window is auto-
matically adjusted based on the distance.
• Wind direction is automatically adjusted if
there are more than 2 people in each area.
• For the wind level, power wind is set as
default for the motion-eye sensor opera-
tion.