Summary of Contents for SM282CE NE1

Page 1: ...AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference www lg com P NO MFL42132810 TYPE FLOOR STANDING MODEL SM282CE NE1 SM282CE UE1 MFL42132810 ENGLISH ESPAÑOL ...

Page 2: ...ir flow or weaken the cooling dehumidifying functions Do not turn on off the air conditioner frequently For inverter product the air conditioner reduces the operating frequency to run super energy saver mode as it gets closer to the set temperature Therefore turning the product on off can lead to higher electricity bill Using the fan together with the air conditioner can keep the space cool as set...

Page 3: ...ting of the air conditioner Fail ure to do so may result in electric shock or product failure Contact an authorized service center when you install or relocate the air conditioner Failure to do so may result in serious injury or product failure Always use a power plug and socket with a ground terminal Failure to do so may result in electric shock or product failure Install the panel and the cover ...

Page 4: ...move the product from the window before hurricane arrives Contact an authorized service center when the air conditioner is submerged into water due to flood ing Failure to do so may result in explosion or fire Be cautious water could not enter the product Make sure to ventilate sufficiently when this air conditioner and a heating appliance such as a heater are used simultaneously Failure to do so ...

Page 5: ...e any objects on the air conditioner It may result in product failure Always insert the filter securely after cleaning Clean the filter every two weeks or more often if necessary Do not insert hands or other objects through the air inlet or outlet while the air conditioner is operat ing It may result in electric shock Do not drink the water drained from the air conditioner It may result in serious...

Page 6: ...in their mouth If the children eat the battery immediately consult a doctor If the heat exchanger is contaminated cooling capacity can be reduced and it can cause an error Therefore remove any particles and dust after using the product for a long period of time With the left right discharge outlet open be careful of the corner part of the bottom right corner of the discharge outlet It can cause an...

Page 7: ...onditioner automatically at a set time 16 Canceling the timer setting 16 Setting sleep mode 17 ADVANCED FUNCTIONS 17 Motion eye sensor 17 Direct wind 17 Indirect wind 18 Energy saving cooling mode 18 Forest wind 19 Long power windblast 19 Speed quick cooling 20 Brightness adjustment Child lock 20 Magic light 20 Magic lighting mode 21 Smart air cleaner 22 MAINTENANCE 22 Auto clean operation 22 Air ...

Page 8: ...fficiency heat exchanger Heat exchanger with antibacterial coating helps to keep the air conditioner clean and re duce the electricity bill by improving the en ergy saving performance Air purifying filter TVF filter Total anti Virus Filter charcoal de odorizer filter and 3M HEPA filter removes any fine dust particle and odor and decomposes removes various types of viruses to keep the air inside th...

Page 9: ...t Right Side wing Air outlet left right Magic display Remote controller receiver Magic wing Aroma plus cover Using in Korea only Control box Dual protection filter Air purifying filter BEFORE USE Indoor unit The feature can be changed according a type of model Exterior of the indoor unit can vary by model ...

Page 10: ...ner display Auto dry display Reservation setting display Indoor temperature Set temperature display Wind level display Outdoor operation display Remote controller receiver Start Stop button Outdoor unit Magic display The feature can be changed according a type of model All display areas are turned on Areas shown the display may vary by function and model ...

Page 11: ... than 3 seconds to set the function and repeat again to cancel the function The remote controller will operate normally even when the button lock function is set The remote controller will operate normally even when the magic display is turned off Set Cancel child lock Button can be locked so that the children do not operate the product arbitrarily Set Cancel magic display Use this to turn on off ...

Page 12: ...en send ing cool wind far and for quick and strong cooling On Off button Turns the power on off Temperature adjustment buttons Adjusts the room temperature when cooling Air cleaner button Purifies the air by removing particles that enter the indoor unit A D Operation Select mode button When selecting cooling or dehu midifier Indoor fan speed button Adjusts the fan speed IJ Air flow direction butto...

Page 13: ...ly will not work Do not step on or apply strong impact to the remote controller Do not use the remote controller in wet or humid locations Do not use the remote controller near heater or in hot location The remote controller may not receive the signal in locations with strong light such as 3 wave florescent light or neon sign In cases like these use the remote controller in front of the remote con...

Page 14: ...or and outdoor tempera ture to 5 C 4 Press again to cancel the operation Removing humidity Dehumidifying operation This mode removes excess moisture from an environment with high humidity or in the rainy season in order to prevent mold from setting in This mode adjusts the room temperature and the fan speed automatically to maintain the optimal level of humidity 1 Press to turn on the power 2 Pres...

Page 15: ...of the display screen 2 Press EorF to select the minutes 3 Press p to finish 4 When setting the timer current time and are displayed on the display screen indicating that the desired time is set NOTE Adjusting the air deflector arbitrarily may cause product failure If you restart the air conditioner it starts to operate with the previously set direc tion of air flow so the air deflector may not ma...

Page 16: ...creen in sleep mode Wind level is set to the lowest level Wind level may be different from the wind level displayed on the remote con troller After the reservation time the air condi tioner is automatically turned off NOTE In the Cooling and Dehumidifying modes the temperature increases by 1 C after 30 minutes and by a further 1 C after another 30 minutes for a more comfortable sleep The temperatu...

Page 17: ...ind during cool operation Energy saving effect of direct wind Motion eye sensor automatically controls the wind level and direction as well as cooling temperature based on the location and activ ity of the user and can save up to 50 of energy compared to the common air condi tioner Indirect wind Human sensor detects the activity and num ber of people and sends cool air near the per son so that it ...

Page 18: ...the indoor environment it may be different from the remote controller setting Actual operating condition is the detail dis played on the magic display This mode does not operate in air cleaner only and dehumidifier operation Forest wind This is the function of simulating the pleasant wind from the forest 1 Press to turn on the power 2 Press f repeatedly to select the cooling operation 3 Press T b ...

Page 19: ...ate in dehumid ifier and air cleaner only operation Speed quick cooling This provides quick cooling effect like a cold shower during the hot summer season 1 Press to turn on the power 2 Press f repeatedly to select the cooling operation 3 Press V c is displayed on the display screen It is good to use this function if you want to quickly cool the house after returning home from hot weather outside ...

Page 20: ...he child lock is set Operation setting display area is displayed to show the operating condition Magic light The ambiance of the house will be enhanced with the magic lighting mode to notify the change in operating condition through dim light and shining of jewelry When using the cooling dehumidifier air cleaner forest wind function lighting of vari ous colors show the operating condition and then...

Page 21: ...r of Low Mid High wind When air cleaner only operation is set Press Z when the air conditioner is stopped Press f during the air cleaner operation to use with cool and dehumidifier opera tion Reference The air cleaner capacity of the air condi tioner may not be the same as the cool op eration performance During spring fall and winter only running the air cleaner operation can maintain a pleasant i...

Page 22: ...l 3 3M HEPA filter Replacement cycle 6 months Cannot be washed Find dust particles can be removed up to 99 97 by applying the high efficiency HEPA filter from 3M 4 Dual protection filter Replacement cycle Semi permanent Can be washed By applying the microfiber dual protection filter it not only filters the large dust but also fine dust particles CAUTION Turn off the power and unplug the power cord...

Page 23: ...le on the inner side of the filter case to take out the filter 3 Soak the dual protection filter in water with neutral detergent for 1 2 hours and then sufficiently rinse with clean water When drying the filter avoid direct sun light and leave in the shades TVF filter charcoal deodorizer and 3M HEPA filter cannot be washed Refer to the filter life and replace accord ingly The application of the fi...

Page 24: ...ft cloth to clean the product CAUTION When cleaning the dual protection filter separate the filter first before cleaning For safety reasons unplug the power plug after turning off the product and then clean the product NOTE The service center will clean the filter at cost based on the request Reference This product does not have any covers for the indoor and outdoor units Indoor unit Door and full...

Page 25: ...or temperature Set the temperature lower than the indoor temperature Is the unit operating in dehumidifier or air cleaner only operation Select the cool operation Is the cool air going out doors Close all open windows and fill up the gaps Is the sunlight coming directly indoors Block the sunlight with curtain etc Is there a heater in doors Do not use with the product that emits heat Isn t the dist...

Page 26: ...rk Is the reservation done correctly Refer to the manual and set the reservation again Pressing Start Stop on the remote controller switches to cool opera tion during air cleaner operation Did you press the Start Stop button on the remote controller when the remote controller display is turned off Press the Start Stop button on the remote controller once again to stop the product Dew drops are for...

Page 27: ... opera tion There is a weird noise in the air conditioner Is the power cord con nected or is the main power switch pulled up Immediately after the power is connected to the product it will run the initialization opera tion There is a weird noise in the air conditioner If the left right and up down wind is set it runs the initialization operation once every 10 operations The initialization operatio...

Page 28: ...28 TROUBLESHOOTING ENGLISH Spec sheet MODEL VOLTAGE COOLING HEATING INPUT CURRENT INPUT CURRENT SM282CE NE1 220V 2200W 10 8A SM282CE UE1 220V 2200W 10 8A ...

Page 29: ...TRONICS MEXICO S A DE C V Sor Juana Inés de la Cruz No 555 Col San Lorenzo Industrial Tlalnepantla de Baz Estado de México C P 54033 Teléfono 55 5321 1919 Sin Costo 01800 3471919 Pagina Web http www lg com mx ...

Reviews: