-11-
■
Remote Control Operation Mode
• When the remote control is selected b y the slide switch on the main unit, the appliance oper ates according to
the input by the remote control.
■
Protection of the evaporator pipe from frosting
• If the indoor pipe temp is belo w 0°C in 7 min. after the compressor oper ates without any pause while in cool-
ing cycle oper ation mode, the compressor and the outdoor f an are tur ned off in order to protect the indoor
evaporator pipe from frosting.
• When the indoor pipe temp is 7 °C or higher after 3 min. pause of the compressor , the compressor and the
outdoor fan is turned on according to the condition of the room temperature.
■
Buzzer Sounding Operation
• When the appliance-operation key is input by the remote control, the short "beep-beep-" sounds.
• When the appliance-pause key is input by the remote control, the long "beep—" sounds.
• When a k ey is input b y the remote control while the slide s witch on the main unit of the appliance is on the
forced operation position, the error sound "beep-beep-beep-beep-beep-" is made 10 times to indicate that the
remote control signal cannot be received.