BEFORE USE
11
ENGLISH
Minimum clearances between
the various parts of the unit
and the surrounding frame-
work
Indoor unit
- Do not have any heat or steam near the unit.
- Select a place where there are no obstacles
in front of the unit.
- Make sure that condensation drainage can
be conveniently routed away.
- Do not install near a doorway.
- Ensure that the interval between a wall and
the left (or right) of the unit is more than
100mm. The unit should be installed as high
as possible on the wall, allowing a minimum
of 200mm from ceiling.
- Use a stud finder to locate studs to prevent
unnecessary damage to the wall.
* The feature can be changed according to a
type of model.
(Unit : mm)
More than 200mm
More than
100mm
More than 2300mm
More than
100mm
CAUTION
Install the indoor unit on the wall where
the height from the floor is more than
2300mm.
!
More than
300mm
More than 300mm
More
than 600mm
More than 600mm
More than 700mm
Outdoor unit
- If an awning is built over the unit to prevent
direct sunlight or rain exposure, make sure
that heat radiation from the condenser is not
restricted.
- Ensure that the space around the back and
sides is more than 300mm. The front of the
unit should have more than 700mm of
space.
- Do not place animals and plants in the path
of the warm air.
- Take the weight of the air conditioner into ac-
count and select a place where noise and vi-
bration are minimum.
- Select a place where the warm air and noise
from the air conditioner do not disturb neigh-
bors.