- 17 -
TROUBLE SHOOTING GUIDE
4. No Raster
(1) Symptom
¯
Does’t minute discharge at module.
¯
It maintains the condition where the front LED is green.
Is output the normality Low/High
Replace
Y-Board.
After connecting well each connector,
Is normal the output voltage after
remove P1, 2, 101, 300, 701, 702
Is normal the Fuse(F52) on Y-B/D?
Replace
Z-Board.
Is normal the Fuse(FS1, FS2) on Z-
B/D? (In case of open is replace)
Is normal the output voltage after
remove P1, 2, 3, 4, 6, 7 connector of
Is normal the output voltage after
After crisis COF of each board, check the normality operates.
If in case normality operates, correspondence COF Fail is
replace the module.
Is normal the
COF of X, Y, Z?
No