ADJUSTMENT INSTRUCTION
1. Application Object
This instruction is for the application to the LCD TV, ML-
024B/C.
2. Notes
(1) This LCD TV has power within set. Connect the power
correctly, then start the adjustment.
(2) The adjustment must be performed under the correct
sequence.
(3) The adjustment must be performed in the circumstance of
25
5 C of temperature and 65
10% of relative humidity
if there is no specific designation.
(4) The set must be operated for 15 minutes preliminarily
before adjustment if there is no specific designation.
O
‘Heat Run’ must be performed with the full white signal or TV
noise signal in the internal part of the set.
O
The time for ‘Heat Run’ can be changed owing to production
plan.
O
Condition of Line Test : Standard color signal - 65!1dBuV
3. RGB LEVEL Adjustment
3-1. Required Test Equipment
(1) PATTERN GENERATOR is possible 10 STEP(408NPS-
READER)
(2) Remote control for adjustment
3-2. Preparation for Adjustment
(1) Select the RGB LEVEL by pressing the ADJ Key(or SVC
Key) on the remote controller for adjustment.
(2) Using the VOL + KEY and it selects.
(3) Using the VOL +/- KEY from R-DRIVE item, adjust 9th and
10th STEP LEVEL until the point does not become
classification.
(4) Adjust the same method in G-DRIVE and B-DRIVE.
(5) When the adjustment is completed, pressing the ENTER
Key to exit.
4. Option
No.
1
2
3
COMPO
3SYS
BLUEB
0
0
1
Component input mode
0 : not ready
1 : ready
Video input applicable system
0 : NTSC-M(North America)
1 : NTSC-M & PAL-M/N multi(South America)
No - signal Video mode
0 : Black-Back
1 : Blue-Back
Item
Specification
Remark