- 3 -
SAFETY PRECAUTIONS
Many electrical and mechanical parts in this chassis have special safety-related characteristics. These parts are identified by in
the Schematic Diagram and Replacement Parts List.
It is essential that these special safety parts should be replaced with the same components as recommended in this manual to
prevent X-RADIATION, Shock, Fire, or other Hazards.
Do not modify the original design without permission of manufacturer.
General Guidance
An
isolation Transformer should always be used
during
the servicing of a receiver whose chassis is not isolated from
the AC power line. Use a transformer of adequate power rating
as this protects the technician from accidents resulting in
personal injury from electrical shocks.
It will also protect the receiver and it's components from being
damaged by accidental shorts of the circuitry that may be
inadvertently introduced during the service operation.
If any fuse (or Fusible Resistor) in this TV receiver is blown,
replace it with the specified.
When replacing a high wattage resistor (Oxide Metal Film
Resistor, over 1W), keep the resistor 10mm away from PCB.
Keep wires away from high voltage or high temperature parts.
Due to high vacuum and large surface area of picture tube,
extreme care should be used in
handling the Picture Tube
.
Do not lift the Picture tube by it's Neck.
X-RAY Radiation
Warning:
To determine the presence of high voltage, use an accurate
high impedance HV meter.
Adjust brightness, color, contrast controls to minimum.
Measure the high voltage.
The meter reading should indicate
23.5
¡
1.5KV: 14-19 inch, 26
¡
1.5KV: 19-21 inch,
29.0
¡
1.5KV: 25-29 inch, 30.0
¡
1.5KV: 32 inch
If the meter indication is out of tolerance, immediate service
and correction is required to prevent the possibility of
premature component failure.
Before returning the receiver to the customer,
always perform an
AC leakage current check
on the exposed
metallic parts of the cabinet, such as antennas, terminals, etc.,
to be sure the set is safe to operate without damage of
electrical shock.
Leakage Current Cold Check(Antenna Cold Check)
With the instrument AC plug removed from AC source,
connect an electrical jumper across the two AC plug prongs.
Place the AC switch in the on position, connect one lead of
ohm-meter to the AC plug prongs tied together and touch other
ohm-meter lead in turn to each exposed metallic parts such as
antenna terminals, phone jacks, etc.
If the exposed metallic part has a return path to the chassis, the
measured resistance should be between 1MΩ and 5.2MΩ.
When the exposed metal has no return path to the chassis the
reading must be infinite.
An other abnormality exists that must be corrected before the
receiver is returned to the customer.
Leakage Current Hot Check
(See below Figure)
Plug the AC cord directly into the AC outlet.
Do not use a line Isolation Transformer during this check.
Connect 1.5K/10watt resistor in parallel with a 0.15uF capacitor
between a known good earth ground (Water Pipe, Conduit, etc.)
and the exposed metallic parts.
Measure the AC voltage across the resistor using AC
voltmeter with 1000 ohms/volt or more sensitivity.
Reverse plug the AC cord into the AC outlet and repeat AC
voltage measurements for each exposed metallic part. Any
voltage measured must not exceed 0.75 volt RMS which is
corresponds to 0.5mA.
In case any measurement is out of the limits specified, there is
possibility of shock hazard and the set must be checked and
repaired before it is returned to the customer.
Leakage Current Hot Check circuit
The source of X-RAY RADIATION in this TV receiver is the
High Voltage Section and the Picture Tube.
For continued X-RAY RADIATION protection, the
replacement tube must be the same type tube as specified in
the Replacement Parts List.
1.5 Kohm/10W
To Instrument's
exposed
METALLIC PARTS
Good Earth Ground
such as WATER PIPE,
CONDUIT etc.
AC Volt-meter
IMPORTANT SAFETY NOTICE
0.15uF
Summary of Contents for RE-39NZ40RB
Page 20: ... 20 TROUBLE SHOOTING ...
Page 21: ... 21 ...
Page 22: ... 22 ...
Page 23: ... 23 ...
Page 24: ... 24 ...
Page 25: ... 25 ...
Page 26: ... 26 ...
Page 27: ... 27 ...
Page 28: ... 28 BLOCK DIAGRAM SIGNAL RT PRT PRT PRT ...
Page 29: ... 29 BLOCK DIAGRAM SIGNAL RE RL PRT PRT PRT ...
Page 31: ...MEMO 31 ...
Page 32: ... 32 PRINTED CIRCUIT BOARD MAIN1 ...
Page 34: ... 34 MAIN2 DEF ...
Page 36: ... 36 SMPS ...
Page 38: ... 38 PRT CONV OUT ...
Page 39: ... 39 POWER S W SIDE AV CONTROL PRE AMP ...
Page 40: ... 40 SVM INTERFACE CONTROL CONVERGENCE INTERFACE ...
Page 41: ... 41 CONVERGENCE TOP CONVERGENCE BOTTOM ...
Page 42: ... 42 MICOM TOP MICOM BOTTOM ...
Page 43: ... 43 100HZ TOP 100HZ BOTTOM ...
Page 44: ...AV TOP 44 AV BOTTOM ...
Page 45: ... 45 AUTO CVG SENSOR TOP AUTO CVG SENSOR BOTTOM ...
Page 46: ... 46 HARMONICS ...
Page 47: ...MEMO 47 ...
Page 50: ...SVC SHEET 3854V A0094D S1 3854V A0094D S2 3854V A0094D S3 ...
Page 87: ...P NO 3854VA0094D S1 1 2 2003 03 13 PRT ...
Page 88: ...P NO 3854VA0094D S1 2 2 2003 03 13 ...
Page 89: ...P NO 3854VA0094D S2 1 2 2003 03 13 ...
Page 90: ...P NO 3854VA0094D S2 2 2 2003 03 13 ...