DIAGOSTIC TEST
11
22
Test 2 DOOR SWITCH / LAMP CHECK
Trouble Symptom : Malfunction of lamp operation and door switch
No operation of pump motor
Displays “ ” in case of the door closed.
The door must be closed and start.
Check door switch
movement.
- See the left picture.
Check and replace lamp.
- See the 14,16 page
• Door switch is working
normally.
• Replace door hook and
close the door.
• Door frame is distorted
• Check door switch
- See 16 page
Measurement condition : Check if they are working while being connected to power supply.
When door is closed, lamp
turns off?
When "Start" button is
pressed, the dryer is working?
When door is opened, lamp
turns on?
(Tumbling stops)
When door is opened or
closed, door switch hook is
not broken?
Check or replace Controller Assembly
Replace Harness and connector
• With door closed, when
"Start" button is pressed,
lamp turns off and
controller is working, but
the dryer is not working.
• With door closed, check voltage of
connector RLY and YL3
which are pulled out from
controller in advance. The voltage
range is between AC 215~245V?
2
1