background image

Error mode and action

Does not

light up

initially

Lamp goes
off trying to

turn on

Lamp is dark

Check whether the power
cord and other internal
wiring is done correctly

Check for any issue on L, N,
GND and internal wiring

Check wiring based
on installation
standard and internal
wiring

Check whether the fuse is
disconnected

Separate the noise filter box of
the power supply and visually
check whether the fuse is
disconnected

Replace PSM (Power
Supply Module)

Check system power
consumption

After checking the power
consumption using the
measuring device, check
whether it is normal

If normal, replace the
bulb assembly

Replace generator
assembly

Check whether DC fan of
LDM part is operating
normally

Check system DC fan cable

Connect the cable

Replace DC fan

Check error check mode:
Flash error LED 1 time

Check error check mode:
Flash error LED 2 times

Check the input power voltage

Check whether BLDC rotates

Replace bulb assembly

Connect the cable

Check BLDC cable wiring

Error mode

* Caution: First, check whether the power cord is unplugged from the outlet and then check/repair

according to the safety precaution and procedure. 

Check point

Check method

Action item 1

Action item 2 

(If not resolved by action item 1)

16

6. Troubleshooting

Check error check mode:
Flash error LED 5 times

Check whether PSM cooling
fan is operating and whether
there is any issue with wiring

Connect the cable

Replace DC fan

Check system power
consumption

Check the system power
consumption using the
measuring device

Replace PSM 

Replace generator
module

Check resonator condition Check if the resonator is

crushed or have any holes

Replace LDM (Light
Drive Module)

Check error check mode:
Flash error LED 1 time

Check input power voltage

Summary of Contents for PSF1032A

Page 1: ...PLS Plasma Lighting System SERVICE MANUAL Caution Please read the Safety precaution before repairing the product Model PSF1032A ...

Page 2: ...nment guide 6 Installation method and example 7 10 Example of incorrect installation 11 5 Operating principle and description Block diagram 12 PLS operating order 13 Drive PCB diagram 14 15 6 Troubleshooting Error mode and action 16 Error check mode and resolution 17 Error cancelation method 17 7 Disassembly diagram 18 8 Replacement parts list 19 ...

Page 3: ...heck and replacement method for electric parts When checking the electric part immediately after disconnecting the power discharge the high voltage part of the PCB before doing so High voltage capacitor and lightron high voltage charge can cause electric shock When the electricity is connected never touch the power circuit High voltage of DC 3500V 4000V is generated on the high voltage part Do not...

Page 4: ...K 80 Ra L570 x W440 x H680 mm 21 kg Block overcurrent above specification 250 V 10 A Prevent overheating of LTN 130 C 70 C CLASSIFICATION SPECIFICATION 2 Product specification No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Optical spectrum near natural light Comfortable lighting Lighting speed of 20 seconds Long life with high optical speed and high color rendering Environment friendly lighting device with h...

Page 5: ...5 Case Upper Glass Cover Cover Top Case Lower Bolt Aiming Angle Cover Front Tilt Swivel Power Supply Cover Side Cover Back Cable High Voltage Power Cord Plug less 3 Exterior and name ...

Page 6: ...igh rise building Indoor Large building Indoor Square or play field Park Large bulletin board Large wall Bridge Environment with high temperature and humidity Environment with use of gas Area with vibration Area with metallic dust Operating time of 24 hours day Operating time of 16 hours day Operating time of 10 hours day Operating time less than 10 hours day Area difficult for A S Wireless LAN In...

Page 7: ...usty area the illumination can be reduced due to the dust Therefore periodically clean the product and do not install the product where metallic dust is generated 7 Install at least 1m from the ground clearance distance must be maintained 8 The mark means min distance from PLS to lighted object when install the PLS check the distance from PLS on the optical axis of PLS Installation method and exam...

Page 8: ...or auto flash device PLS is not equipped with a terminal block For installation please get professional assistance Terminal Block Specification a Rated Voltage 250V or above b Rated Power 10A or above c 3 way bolt fastening type After connecting power line to the terminal block ensure that the power line makes secure contact with fastening bolt or clamp and the power line is securely fastened WARN...

Page 9: ...ate separately to fixate the product Refer to the following drawing Not included in the product If the base plate is not required install the product by considering the cooling path Inlet Outlet of the system When manufacturing the base plate to fixate the product always use steel plate of L400xW272 mm 5T or above Units mm 231 252 13 10 59 70 40 400 110 255 0 400 0 12 0 80 0 30 0 80 0 30 0 80 0 50...

Page 10: ...et Spring Washer M8 Nut Base plate to fixate product Base Plate Power supply PSM Inlet Install the product on even ground free from submersion When adjusting the bolt M12 bolt aiming angle to adjust the PLS angle always use a spanner and maintain torque of 40kgf cm or above ...

Page 11: ...oduct with flammable material around the product When disassembling while the product is operating When repairing or disassembling the product by an unqualified technician When using in environment where alien particles penetrate into the suction inlet exhaust outlet When cleaning or repairing the product while operating the product When touching the power cord with wet hands When using the produc...

Page 12: ...12 5 Operating principle and description Block Diagram ...

Page 13: ...13 PLS operating order ...

Page 14: ...power LED P901 DC fan connector P900 SYS fan bulb MTR connector VR800 output volume control P301 Ext PGM loading terminal LED 300 error display S300 error cancel switch P601 high voltage earth terminal P600 high voltage 4kV terminal PSF1032A PCB ASSEMBLY INVERTER ...

Page 15: ...15 LED error display No 1 Input voltage error No 2 BLDC error No 4 Input current error No 5 Inverter internal temperature error PSF1032A LED error display ...

Page 16: ...an Check error check mode Flash error LED 1 time Check error check mode Flash error LED 2 times Check the input power voltage Check whether BLDC rotates Replace bulb assembly Connect the cable Check BLDC cable wiring Error mode Caution First check whether the power cord is unplugged from the outlet and then check repair according to the safety precaution and procedure Check point Check method Acti...

Page 17: ...ether the PSM cooling fan is operating Error LED on and off 5 times P Supply Inne Temperature Error Check Error display Error detail Check limit Check point Error cancelation method Control PCB error Cancel error using clear switch 1 Turn on power line 2 Check error LED 3 Press the error clear switch for 2 seconds Wait until the flashing LED is turned off 4 Wait 30 seconds after the power line is ...

Page 18: ...18 7 Disassembly diagram 301 102 101 305 201 306 202 302 104 103 401 402 403 404 304 303 307 308 405 406 309 310 ...

Page 19: ... 303 MCK62733701 Cover Side Casting ADC12 290 200 155 EA 1 304 MCK62733801 Cover Rear Casting ADC12 200 200 63 EA 1 305 3043Z FB02A Supporter Assembly Flood900 SP EA 1 306 3111300001A Case Assembly PSF09 EA 1 307 3110Z L006A Case Rear AL Diecasting EA 1 308 3550Z T006A Cover Top AL Diecasting EA 1 309 MDS39999701 Gasket Packing Complex Plate Waveguide EA 1 310 3550Z F005A Cover Front AL Diecasting...

Page 20: ... Service inquiry and contact Tel 1544 5472 Fax 055 268 4585 Address PLS Part 76 Seongsan dong Changwon city Gyeongnam Korea October 2010 Printed in Korea P No MFL62883503 ...

Reviews: