Wired remote controller switch information
6
Simple Wired Remote Controller
Wired remote controller switch information
S/W 1
SW
±
GR
SW
±
HI
Room Temp. Sensing
Ceiling Height/Default E.S.P
Group Control
3
1
2
2
SW
±
PD
SW
±
TH
Select Product
2
1
1
3 2 1
Group control switch
1. For individual control/Master use
2. For group control/Slave use
Ceiling height selection switch
1. Low ceiling
2. Standard ceiling
3. High ceiling
Product selection switch
1. Cooling Only product
2. Heat Pump product
Indoor temperature sensor
selection switch
1. Use the temperature sensor on the remote
controller.
2. Use the temperature sensor on the product.
3. Use the sensors on the product and remote
controller.
• When changing the product selection switch and group control switch, the power must be reconnected to reflect
the changes.
• The central control could operate inappropriately depends on indoor unit type, when the remote controller is set
as slave.