b) For Secam-L' system
1) Turn on DC power supplies.
2) Apply 5Vdc to the + lead of C25.
3) Adjust VCO adjust volume(
VR102
) so that the DMM reads 2.5Vdc+_0.1V.
* Scr een v oltage adjustment
1) Tune the TV set to receive digital pattern.
2) Press PSM button on the Remote Controller to get the STANDARD picture.
3) Turn the screen VR of FBT until the black level of picutre signal is 150Vdc at the digital pattern.
IC101
TDA4474
C123(+)
GND(C122(-))
Multimeter &
oscilloscope
2.5Vdc
SW1
SW2
24
3
4
5
VR102
J139 GND
5V
AM/FM SW
L/L'SW
Z102
G3953
J77
12Vdc
R124
C25(+)
R169
C25(-)
Power
Supply
GND(C26(-))
33.9MHz
Signal
generator
GND
Ceramic
CAP.
10000pF
Ceramic
CAP.
10000pF
MAIN BOARD
Fig. 2 : Connecting Diagram of Equipments for secam-L' system.
Test Poin t :
J5 (one lead of R533)
Adjus t :
VR102
GND
CPT BOARD
OSCILLSCOPE
Rk
BLACK Level
150Vdc 1.5V
Fig. 3
Fig. 4