3-8
ONE POINT REPAIR GUIDE
NO OPERATION OF MD
When no sound output in the CD function, you can not listen to music reading data from a CD disc if
the servo motors in MD don’t work. This step is for checking the TRAY OPEN/CLOSE MOTOR among
them.
4-3. TRAY OPEN/CLOSE MOTOR
4-3-1. Solution
Please check and replace IC407, IC408 on MAIN board.
4-3-2. How to troubleshoot (Countermeasure)
1) Check MOT_OPEN & MOT_CLOSE signals from Pin K4, L4 of IC502 to IC400.
If no signal, check +1.8 V & + 5 V to IC400.
2) Check LOAD± from IC408 to CN401 for driving the tray open / close motor. It is about 3.85 Vp-p.
If no signal, check +5 V to IC400. If it has any trouble, replace it with a new one.
3) Check if the FFC cable is solidly connected between CN401 and MD.
4) Check the MD.
If the tray motor is sort-circuit or has any trouble, it can not open or close the tray.
Please check the function after changing another MD.
4-3-3. Service hint (Any picture/ Remark)
< Waveform for driving
TRAY open/close motor >
< Signal check point >
MOT_OPEN
MOT_CLOSE
LO- to CN401
LO+ to CN401