1. Multiple piping type MULTI F
14
_ Heat Pump
60Hz/R410A
Part 2 Product data_Outdoor units
7 7 7 12 18 51 1.5 1.5 1.5 2.6 4.0 22,920 6.7 38,200 11.2 46,000 13.5 1,693 2,730 4,150
7 9 12 12 12 52 1.5 1.9 2.6 2.6 2.6 22,920 6.7 38,200 11.2 46,000 13.5 1,693 2,730 4,150
7 9 9 9 18 52 1.5 1.9 1.9 1.9 3.9 22,920 6.7 38,200 11.2 46,000 13.5 1,693 2,730 4,150
7 7 7 7 24 52 1.5 1.5 1.5 1.5 5.2 22,920 6.7 38,200 11.2 46,000 13.5 1,693 2,730 4,150
7 7 9 12 18 53 1.5 1.5 1.9 2.5 3.8 22,920 6.7 38,200 11.2 46,000 13.5 1,693 2,730 4,150
7 7 7 9 24 54 1.5 1.5 1.5 1.9 5.0 22,920 6.7 38,200 11.2 46,000 13.5 1,693 2,730 4,150
9 9 9 9 18 54 1.9 1.9 1.9 1.9 3.7 22,920 6.7 38,200 11.2 46,000 13.5 1,693 2,730 4,150
9 9 12 12 12 54 1.9 1.9 2.5 2.5 2.5 22,920 6.7 38,200 11.2 46,000 13.5 1,693 2,730 4,150
7 9 9 12 18 55 1.4 1.8 1.8 2.4 3.7 22,920 6.7 38,200 11.2 46,000 13.5 1,693 2,730 4,150
7 12 12 12 12 55 1.4 2.4 2.4 2.4 2.4 22,920 6.7 38,200 11.2 46,000 13.5 1,693 2,730 4,150
5 Unit 7 7 9 9 24 56 1.4 1.4 1.8 1.8 4.8 22,920 6.7 38,200 11.2 46,000 13.5 1,693 2,730 4,150
7 7 12 12 18 56 1.4 1.4 2.4 2.4 3.6 22,920 6.7 38,200 11.2 46,000 13.5 1,693 2,730 4,150
7 7 7 12 24 57 1.4 1.4 1.4 2.4 4.7 22,920 6.7 38,200 11.2 46,000 13.5 1,693 2,730 4,150
7 7 7 18 18 57 1.4 1.4 1.4 3.5 3.5 22,920 6.7 38,200 11.2 46,000 13.5 1,693 2,730 4,150
9 9 9 12 18 57 1.8 1.8 1.8 2.4 3.5 22,920 6.7 38,200 11.2 46,000 13.5 1,693 2,730 4,150
9 12 12 12 12 57 1.8 2.4 2.4 2.4 2.4 22,920 6.7 38,200 11.2 46,000 13.5 1,693 2,730 4,150
7 9 9 9 24 58 1.4 1.7 1.7 1.7 4.6 22,920 6.7 38,200 11.2 46,000 13.5 1,693 2,730 4,150
7 9 12 12 18 58 1.4 1.7 2.3 2.3 3.5 22,920 6.7 38,200 11.2 46,000 13.5 1,693 2,730 4,150
7 7 9 12 24 59 1.3 1.3 1.7 2.3 4.6 22,920 6.7 38,200 11.2 46,000 13.5 1,693 2,730 4,150
7 7 9 18 18 59 1.3 1.3 1.7 3.4 3.4 22,920 6.7 38,200 11.2 46,000 13.5 1,693 2,730 4,150
9 9 9 9 24 60 1.7 1.7 1.7 1.7 4.5 22,920 6.7 38,200 11.2 46,000 13.5 1,693 2,730 4,150
9 9 12 12 18 60 1.7 1.7 2.2 2.2 3.4 22,920 6.7 38,200 11.2 46,000 13.5 1,693 2,730 4,150
12 12 12 12 12 60 2.2 2.2 2.2 2.2 2.2 22,920 6.7 38,200 11.2 46,000 13.5 1,693 2,730 4,150
Combination
(kBtu/h)
Each capacity
(kW)
Total Capacity (kW)
Cooling
Min
Rated
Max
Input
(W)
Unit-A Unit-B Unit-C Unit-D Unit-E Total Unit-A Unit-B Unit-C Unit-D Unit-E Btu/h
kW
Btu/h
kW
Btu/h
kW
Min
Rated Max
Operation
Note :
1. Cooling Capacity is based on : indoor temp. 27°CDB, 19°CWB
; outdoor temp. 35°CDB, 24°CWB
2. Heating Capacity is based on : indoor temp. 20°CDB, 15°CWB
; outdoor temp. 7°CDB, 6°CWB
3. Maximum total capacity index of connected indoor units is 60kBtu/h
4. At least two indoor units should be connected to outdoor unit.
5. Total capacity of indoor units connected should be minimum 40% of outdoor unit rated capacity.