A. PRIMARY INTERLOCK SWITCH TEST
When the door release button is depressed slowly
with the door closed, an audible
click
should be
heard at the same time or successively at
intervals. When the button is released slowly, the
latches should activate the switches with an
audible
click
.
If the latches do not activate the switches when
the door is closed, the switches should be a
adjusted in accordance with the adjustment
procedure. Disconnect the wire lead from the
primary switch. Connect the ohmmeter leads to
the common (COM) and normally open (NO)
terminal of the switch. The meter should indicate
an open circuit in the door open condition.
When the door is closed, the meter should
indicate a closed circuit.
When the primary switch operation is abnormal,
make the necessary adjustment or replace the
switch only with the same type of switch.
B. SECONDARY INTERLOCK SWITCH TEST
Disconnect the wire lead from the secondary
switch.
Connect the ohmmeter leads to the common
(COM) and normally open (NO) terminals of the
switch. The meter should indicate a open circuit in
the door open condition. When the door is closed,
meter should indicate an closed circuit. When the
secondary switch operation is abnormal, make the
necessary adjustment or replace the switch only
with the same type of switch.
C. MONITOR SWITCH TEST
Disconnect the wire lead from the monitor switch.
Connect the ohmmeter leads to the common
(COM) and normally closed (NC) terminals of the
switch. The meter should indicate closed circuit in
the door open condition. When the door is closed,
meter should indicate an open circuit. When the
monitor switch operation is abnormal, replace with
the same type of switch.
NOTE: After repairing the door or the interlock
system, it is necessary to do this continuity
test before operating the oven.
5-7
WARNING : FOR CONTINUED PROTECTION AGAINST EXCESSIVE RADIATION
EMISSION, REPLACE ONLY WITH IDENTICAL REPLACEMENT PARTS.
TYPE NO.SZM-V 16-FA-63 OR VP-533A-OF FOR PRIMARY SWITCH
TYPE NO.SZM-V 16-FA-62 OR VP-532A-OF FOR MONITOR SWITCH
TYPE NO.SZM-V 16-FA-63 OR VP-533A-OF FOR SECONDARY SWITCH
COMPONENTS
TEST PROCEDURE
RESULTS
SWITCHES
Check for continuity of the
Door
Door
(Wire leads removed)
switch with an Ohm-meter
open
closed
Primary
Switch
Monitor
Switch
NOTE :
After checking for the continuity of switches, make sure that are
correctly connected.
COM
NO
COM
NC
COM
NO
INTERLOCK CONTINUITY TEST
Secondary
Switch
LGE Internal Use Only
Copyright © 2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Summary of Contents for MS1949G
Page 29: ... 6 2 13552A 13213A 13581A 13720D 14970A 14026A 13536A 14890A DOOR PARTS EV ...
Page 30: ... 6 3 23506A 24781M 23572A 24510L 250201 24970A 268711 WTT028 CONTROL PANEL PARTS EV ...
Page 31: ... 6 4 33390G 35889A WTT021 33112U WTP013 36549S 33052A OVEN CAVITY PARTS EV ...
Page 32: ... 6 5 56912B 55262A 43501A 466001 466001 43500A 466003 WSZ085 LATCH BOARD PARTS EV ...
Page 34: ... 6 7 56170D 63302A 63303A WTT021 WSZ002 65006B 65006B BASE PLATE PARTS EV ...
Page 35: ......