background image

TABLE OF CONTENTS

2

TIPS FOR SAVING ENERGY

3

IMPORTANT SAFETY 
INSTRUCTIONS

7

BEFORE USE

7

Components

8

Using the remote control

9

- Inserting batteries

9

- Installing the remote control holder

10

BASIC FUNCTIONS

10

Cooling your room

10

Heating your room

10

Removing humidity

11

Airing your room

11

Adjusting the fan speed

11

Adjusting the air flow direction

11

Setting the timer

11

- Setting the current time

12

- Turning on the air conditioner 

automatically at a set time

12

- Turning off the air conditioner 

automatically at a set time

12

- Canceling the timer setting

12

- Setting sleep mode

13

ADVANCED FUNCTIONS

13

Changing room temperature quickly

13

Indoor air purification

13

- Auto Clean operation

14

Plasma Purification operation

14

Auto operation

15

Energy saving cooling mode

15

Display screen brightness

15

Operating the air conditioner without the
remote control

16

Restarting the air conditioner 
automatically

17

MAINTENANCE

18

Cleaning the air filter

18

Cleaning the anti-allergy filter and triple
filter

18

Cleaning the plasma filter

19

TROUBLESHOOTING

19

Self-diagnosis function

19

Before requesting service

TABLE OF CONTENTS

6

ENGLISH

Summary of Contents for MS09AQ

Page 1: ...ER Please read this manual carefully before operating your set and retain it for future reference www lg com TYPE WALL MOUNTED P NO MFL67482001 ENGLISH ITALIANO ESPAÑOL FRANCAIS DEUTSCH ΕΛΛΗΝΙΚΆ PORTUGUESE NEDERLANDS POLSKI MAGYAR ...

Page 2: ...irection of the air flow vertically or horizontally to circulate indoor air Speed up the fan to cool or warm indoor air quickly in a short period of time Open windows regularly for ventilation as the indoor air quality may deteriorate if the air con ditioner is used for many hours Clean the air filter once every 2 weeks Dust and impurities collected in the air filter may block the air flow or weak...

Page 3: ...d wire to gas or water pipes lightening rod or telephone ground wire There is risk of fire or electric shock Install the panel and the cover of control box securely There is risk of fire or electric shock due to dust water etc Use the correctly rated breaker or fuse There is risk of fire or electric shock Do not modify or extend the power cable If the power cable or cord has scrathes or skin peele...

Page 4: ...f the unit is so equipped There is risk of physical injury electric shock or product failure If strange sound smell or smoke comes from product Immediately turn the breaker off or discon nect the power supply cable There is risk of electric shock or fire Ventilate the product room from time to time when operating it together with a stove or heating el ement etc Oxygen deficiency can occur and henc...

Page 5: ...ot mix air or gas other than the specified refrigerant used in the system If air enters the refrig erant system an excessively high pressure results causing equipment damage or injury If the refrigerant gas leaks during the installation ventilate the area immediately Otherwise it can be harmfull for your health Dismantling the unit treatment of the refrigerant oil and eventual parts should be done...

Page 6: ...Turning off the air conditioner automatically at a set time 12 Canceling the timer setting 12 Setting sleep mode 13 ADVANCED FUNCTIONS 13 Changing room temperature quickly 13 Indoor air purification 13 Auto Clean operation 14 Plasma Purification operation 14 Auto operation 15 Energy saving cooling mode 15 Display screen brightness 15 Operating the air conditioner without the remote control 16 Rest...

Page 7: ...er Air filter Front grille Vertical louver Air outlet Horizontal vane Horizontal vane Horizontal vane Triple filter NOTE The number of operation lamps and their locations may vary depending on the model of the air conditioner 7 BEFORE USE ENGLISH Indoor unit The feature can be changed according a type of model ...

Page 8: ...e power on off g 7v Indoor fan speed button Adjusts the fan speed f A C D B E Operation mode selection button Se lects the operation mode Cooling operation A Auto operation C Dehumidifying operation D Heating operation B Air circulation E h N Jet cooling heating button Warms up or cools down the indoor temperature within a short period of time i j H I Air flow direction button Adjusts the air flow...

Page 9: ... accessible place 2 Fix the holder by fastening the 2 screws firmly with a screwdriver 3 Slide the remote control into the holder Point the remote control towards the signal receiver at the bottom of the air conditioner to operate it NOTE If the display screen of the remote control starts to fade replace the batteries NOTE The remote control may operate other electronic devices if pointed towards ...

Page 10: ... range is 16 C 30 C Removing humidity Dehumidifying operation This mode removes excess moisture from an environment with high humidity or in the rainy season in order to prevent mold from setting in This mode adjusts the room temperature and the fan speed automatically to maintain the optimal level of humidity 1 Press d to turn on the power 2 Press f repeatedly to select the dehu midifying operati...

Page 11: ...ction of the air flow verti cally press j repeatedly and select the desired direction Select I to adjust the direction of the air flow automatically Setting the timer You can use the timer function to save energy and to use the air conditioner more efficiently Setting the current time 1 Press p and hold it for longer than 3 sec onds The AM PM icon flickers at the bottom of the display screen NOTE ...

Page 12: ...er setting 1 Press m 2 Press m or n to select the timer setting to cancel 3 Press p To cancel all timer settings press p Setting sleep mode Use the sleep mode to turn off the air condi tioner automatically when you go to sleep 1 Press d to turn on the power 2 Press l 3 Press o or q to select the hour up to 7 hours 4 Press p to finish T is displayed on the display screen in sleep mode NOTE In the C...

Page 13: ...nutes Indoor air purification Auto Clean operation In the cooling and dehumidifying operations moisture is generated inside the indoor unit Use the auto cleaning function to remove such moisture 1 Press d to turn on the power 2 Press c J is displayed on the display screen If you turn off the power the fan oper ates for 30 minutes and cleans the inside of the indoor unit NOTE In Air Circulation Aut...

Page 14: ...uto opera tion 3 Press o or q to select the desired oper ation code if the temperature is higher or lower than the desired temperature NOTE You can use this function by pressing a without turning the air conditioner on Both the plasma lamp and the cooling lamp light up while plasma purification is in operation This function may not be supported de pending on the model ADVANCED FUNCTIONS 14 ENGLISH...

Page 15: ...n of the indoor unit to operate the air conditioner when the remote control is unavailable However the fan speed is set to high 1 Open the front cover Lift up both sides of the cover slightly 2 Press the On Off button For cooling and heating models the oper ation mode changes depending on the room temperature 15 ADVANCED FUNCTIONS ENGLISH NOTE This function may not be supported depending on the mo...

Page 16: ...imes To re enable the function press the On Off button and hold it for 6 seconds The unit will beep twice and the blue lamp will blink 4 times ON OFF button Disabling auto restart NOTE If you press and hold the On Off button for 3 5 seconds instead of 6 seconds the unit will switch to the test operation In the test operation the unit blows out strong air for cooling for 18 minutes and then returns...

Page 17: ...er coils and the panel vents consult with technician Anti allergy filter Plasma filter Air filter Triple filter CAUTION Turn off the power and unplug the power cord before you perform any maintenance other wise it may cause electric shock Never use water that is hotter than 40 C when you clean the filters It may cause deforma tion or discoloration Never use volatile substances when you clean the f...

Page 18: ...e and remove the air fil ter see Cleaning air filter 3 Pull out the anti allergy filter and the triple filter 4 Dry the filter in direct sunlight for 2 hours Cleaning the plasma filter 1 Turn off the power and unplug the power cord 2 Open the front grille and remove the air fil ter see Cleaning the air filter 3 Remove the plasma filter in 10 seconds 4 Use a vacuum cleaner to remove any dirt If dir...

Page 19: ...ged or gener ating excessive heat A switch a circuit breaker safety ground or a fuse is not operated properly The air conditioner does not work The air conditioner is unplugged Check whether the power cord is plugged into the outlet A fuse is blown or the power supply is blocked Replace the fuse or check if the circuit breaker has tripped A power failure has occurred Turn off the air conditioner w...

Page 20: ... a heat generator such as an electric oven or a gas burner while the air conditioner is in operation Air circulation opera tion is selected In the air circulation operation air blows from the air conditioner without cooling or heating the indoor air Switch the operation mode to the cooling operation Outside tempera ture is too high The cooling effect may not be sufficient The air conditioner does ...

Page 21: ...Mist is discharged from the air outlet of the indoor unit The cooled air from the air condi tioner makes mist When the room temperature is down this phenomenon will disap pear Water leaks from the outdoor unit In the heating operations con densed water drop from the heat exchanger This symptom need to install drain hose under the base pan Contact the installer Operating noise or vibration Clicking...

Page 22: ...22 ENGLISH ...

Page 23: ......

Reviews: