D. PCB ASSEMBLY REMOVAL
1) Remove the control panel assembly from the
cavity. (Refer to control panel assembly removal
on previous page.)
2) Remove screws which hold the PCB SUB ASS’Y to
the control panel.
3) Disconnect the flat cable from the PCB SUB
ASS’Y and take off the PCB SUB ASS’Y
E. DOOR MAIN ASSEMBLY REMOVAL
1) Open the door.
2) Remove the choke cover very carefully with a flat-blade
screwdriver.
CAUTION: Be careful not to damage door seal plate
by screwdriver.
3) Lift up and push the door.
NOTE:
1. After replacing the door, be sure to check that the
primary switch, monitor switch, and secondary switch
operate normally.
2. After replacing the door, check for microwave energy
leakage with a survey meter. Microwave energy must
be below the limit of 4 mW/cm. (with a 275 ml water
load)
3. When mounting the door assembly to the oven
assembly, be sure to adjust the door assembly parallel
to the chassis. Also adjust so the door has no play
between the inner door surface and oven frame
assembly. If the door assembly is not mounted
properly, microwaves may leak from the clearance
between the door and the oven.
5-4
Door seal plate
Key
Membrane
Door Open
Button
Release
Lever
Button
Spring
Control Panel
PCB Sub Asm
Remove door
Remove choke cover
Spacer
Summary of Contents for MS-324SCE
Page 27: ...6 2 13213A 13552A 13536A 14026A 14970A 13581A 15006A 14890A 13720D ECN Check DOOR PARTS ...
Page 28: ...6 3 23506C 268711 WTT028 24781M 24510L 250201 23572A 24970A ECN Check CONTROLLER PARTS ...
Page 30: ...6 5 55262A 43500A 466003 466001 466001 43501A WSZ085 56912B LATCH BOARD PARTS ...
Page 32: ...6 7 63302L 56170D WSZ002 948503 WTT021 WTT028 647781 63302R 63303L 63303R BASE PLATE PARTS ...
Page 33: ...6 8 WTT021 54974T 56501A 948501 WTP002 ECN Check ECN Check SENSOR PARTS ...