5-13
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Fuse blows.
Continuity.
No continuity.
Continuity.
Shorted contact at
the primary switch.
Replace fuse,
primary, monitor,
secondary
switches, and
RELAY(RY2) of
P.C.B Assembly.
No continuity.
Normal.
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Fuse blows again
Defective high volt-
age transformer.
Replace high volt-
age transformer.
Malfunction of the
monitor switch.
Replace fuse,
primary, monitor,
secondary
switches, and
RELAY(RY2) of
P.C.B Assembly.
Check continuity
of monitor
switch (with
door closed).
Check continuity
of primary
switch (with
door opened).
Disconnect one
side of the wire
lead connected
from transformer
to the high
voltage
capacitor and
operate the unit.
Replace fuse
Continuity.
Malfunction of
secondary switch.
Replace fuse,
primary, monitor,
secondary
switches, and
RELAY(RY2) of
P.C.B Assembly.
No continuity.
Check continuity
of secondary
switch (with
door opened).
2. Fuse does not
blow.
No continuity.
Continuity.
No continuity.
Defective power
supply cord.
Replace power
supply cord.
Defective
thermostat.
Replace
thermostat.
Check continuity
of thermostat.
Check continuity
of power supply
cord.
(TROUBLE 2) Oven does not operate at all, Display window does not display any figures,
and no input is accepted.
NOTE : All these switches must be replaced at the same time. Refer to page 5-7, 5-8
Summary of Contents for MS-324DL
Page 27: ...6 2 13551A 13581A 14970A 14026A 13552A 15006A 13213A 14890A 13536A DOOR PARTS ...
Page 28: ...6 3 23506A 23551B 24970A 23550D 268711 WTP018 24781M 24510L 23551A CONTROLLER PARTS ...
Page 29: ...6 4 35889A 33052M 340511 36549S WTP013 33390G WTT010 WTT021 33112U 34370T OVEN CAVITY PARTS ...
Page 30: ...6 5 43501A WSZ085 466001 466003 466001 43500A LATCH BOARD PARTS ...
Page 32: ...6 7 63302L 63303L 56170D 63302R WSZ002 WTT021 WTT028 647781 63303R 948502 BASE PLATE PARTS ...
Page 33: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Page 34: ...8 2 PRINTED CIRCUIT BOARD ...