![LG MS-256NB Service Manual Download Page 19](http://html.mh-extra.com/html/lg/ms-256nb/ms-256nb_service-manual_1899411019.webp)
5-9
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
CAPACITOR
HIGH VOLTAGE
DIODE
NOTE :
Some inexpensive meters
may indicate infinite
resistance in both direction.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to terminal.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to case.
Measure the continuity (Forward).
(Ohm-meter scale: Rx10000)
Measure the continuity (Reverse).
(Ohm-meter scale: Rx10000)
Normal: Momentarily indicates
several ohms, and
then gradually returns
to infinite.
Normal:
∞
Normal: Continuity.
Abnormal:
∞
Normal:
∞
Abnormal: Continuity.
NOTE: When testing the magnetron, be sure to install the magnetron gasket
in the correct position and be sure that the gasket is in good condition.
Antenna
Gasket
Chassis
Filament