5-9
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
CAPACITOR
HIGH VOLTAGE
DIODE
NOTE :
Some inexpensive meters
may indicate infinite
resistance in both direction.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to terminal.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to case.
Measure the continuity (Forward).
(Ohm-meter scale: Rx10000)
Measure the continuity (Reverse).
(Ohm-meter scale: Rx10000)
Normal: Momentarily indicates
several ohms, and then
gradually returns to
infinite.
Normal:
∞
Normal:
∞
Abnormal: Continuity.
Normal: Continuity.
Abnormal:
∞
NOTE: When testing the magnetron, be sure to install the magnetron gasket
in the correct position and be sure that the gasket is in good condition.
Antenna
Gasket
Chassis
Filament
Summary of Contents for MS-1942G
Page 9: ...SCHEMATIC DIAGRAM 4 3 8 ...
Page 29: ...6 2 13581A 14970A 14026A 13552A 13213A 13352A 13720D 13536A DOOR PARTS EV ...
Page 30: ...6 3 23506A 23572A 268711 WTT021 24781S CONTROL PANEL PARTS EV ...
Page 31: ...6 4 33390G 35889A WTP013 WTT010 WTT021 33112U 36549S 33052A OVEN CAVITY PARTS EV ...
Page 32: ...6 5 WSZ085 44510A 466001 466003 466001 43500A LATCH BOARD PARTS EV ...
Page 34: ...6 7 56170D 63302A 65006B WTT028 WSZ002 63303A 948502 BASE PLATE PARTS EV ...