![LG MS-1902H Service Manual Download Page 19](http://html.mh-extra.com/html/lg/ms-1902h/ms-1902h_service-manual_1899353019.webp)
5-9
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
CAPACITOR
HIGH VOLTAGE
DIODE
NOTE :
Some inexpensive meters
may indicate infinite
resistance in both direction.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to terminal.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to case.
Measure the continuity (Forward).
(Ohm-meter scale: Rx10000)
Measure the continuity (Reverse).
(Ohm-meter scale: Rx10000)
Normal: Momentarily indicates
several ohms, and
then gradually returns
to infinite.
Normal:
∞
Normal: Continuity.
Abnormal:
∞
Normal:
∞
Abnormal: Continuity.
NOTE: When testing the magnetron, be sure to install the magnetron gasket
in the correct position and be sure that the gasket is in good condition.
Antenna
Gasket
Chassis
Filament
Terminals
Summary of Contents for MS-1902H
Page 9: ...SCHEMATIC DIAGRAM 4 3 ...
Page 27: ...6 2 13552A 13213A 13581A 13720D 14970A 14026A 13536A 13352A DOOR PARTS ...
Page 28: ...6 3 24781T 23572A 24510L 250201 24970A 249401 WTP015 26549T CONTROL PANEL PARTS ...
Page 29: ...6 4 33052M 340511 33112U WTT021 34960A 36549S WTP013 33390G 35889A OVEN CAVITY PARTS ...