5-8
COMPONENT TEST PROCEDURE
CAUTIONS
1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE
OUTER CASE FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH
VOLTAGE CAPACITOR AND REMOVING THE WIRE LEADS FROM THE PRIMARY WINDING OF THE
HIGH VOLTAGE TRANSFORMER. (SEE PAGE 2-1)
2. ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1 LITER
OF WATER IN CONTAINER) IN THE OVEN.
HIGH VOLTAGE
TRANSFORMER
(Wire leads removed)
MAGNETRON
(Wire leads removed)
Approx.: 2.13 ±10% ohm
Approx.: 178.19 ±10% ohm
Less than: 1 ohm
Normal: Infinite
Normal: Infinite
Normal: Less than 1 ohm
Normal: Infinite
PRIMARY
TERMINAL
SECONDARY
TERMINAL
WINDING
FILAMENT
TERMINAL
COMPONENTS TEST
PROCEDURE RESULTS
1. Measure the resistance.
(Ohm-meter scale: Rx1 and Rx100)
• Primary winding
• Secondary winding
• Filament winding
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Primary winding to ground
• Filament winding to ground
1. Measure the resistance.
(Ohm-meter scale: Rx1)
• Filament terminal
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Filament to chassis
Summary of Contents for MS-1146SQP
Page 9: ...SCHEMATIC DIAGRAM 4 3 ...
Page 27: ... 6 2 DOOR PARTS 14026A 14970A 13581A 13536A 13552A 13213A 13720D 14890A EV ...
Page 28: ... 6 3 CONTROLLER PARTS 24970A 250201 23572A 268711 24781M 24510L 23506A EV ...
Page 29: ... 6 4 OVEN CAVITY PARTS 33390G 35889A 33112U 36549S 33052A EV ...
Page 30: ... 6 5 LATCH BOARD PARTS 43501A 43500A 466001 466003 466001 WSZ085 EV ...
Page 32: ... 6 7 BASE PLATE PARTS 63303A 56170D WSZ002 EV ...
Page 33: ......