5-8
CAUTIONS
1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE
OUTER CASE FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH
VOLTAGE CAPACITOR AND REMOVING THE WIRE LEADS FROM THE PRIMARY WINDING OF THE
HIGH VOLTAGE TRANSFORMER. (SEE PAGE 2-1)
2. ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1 LITER
OF WATER IN CONTAINER) IN THE OVEN.
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
TRANSFORMER
(Wire leads removed)
MAGNETRON
(Wire leads removed)
1. Measure the resistance.
(Ohm-meter scale: Rx1 and Rx100)
• Primary winding
• Secondary winding
• Filament winding
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Primary winding to ground
• Filament winding to ground
1. Measure the resistance.
(Ohm-meter scale: Rx1)
• Filament terminal
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Filament to chassis
Approx.: 2.0 ohm
Approx.: 150 ohm
Less than: 1 ohm
Normal: Infinite
Normal: Infinite
Normal: Less than 1 ohm
Normal: Infinite
FILAMENT
WINDING
TERMINAL
PRIMARY
TERMINAL
SECONDARY
TERMINAL
COMPONENT TEST PROCEDURE
LGE Internal Use Only
Copyright © 2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Summary of Contents for MJ3284UAB
Page 31: ... 6 2 DOOR PARTS EV 13552A 13581A 14026A 14970A 13213A 13551C 13650A ...
Page 32: ... 6 3 CONTROL PANEL PARTS EV 24781A 26871T 26871M 24781S 250202 250201 249401 24941A ...
Page 34: ... 6 5 W102 43501A 466001 43500A 466003 44510A 466001 LATCH BOARD PARTS EV ...
Page 36: ... 6 7 647781 W101 56170D 63302A 63303A BASE PLATE PARTS EV ...
Page 37: ......