![LG MD-0942GT Service Manual Download Page 19](http://html.mh-extra.com/html/lg/md-0942gt/md-0942gt_service-manual_215719019.webp)
5-9
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
CAPACITOR
HIGH VOLTAGE
DIODE
NOTE :
Some inexpensive meters
may indicate infinite
resistance in both direction.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to terminal.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to case.
Measure the continuity (Forward).
(Ohm-meter scale: Rx10000)
Measure the continuity (Reverse).
(Ohm-meter scale: Rx10000)
Normal: Momentarily indicates
several ohms, and then
gradually returns to
infinite.
Normal: Infinite.
Normal: Continuity.
Abnormal: Infinite.
Normal: Infinite.
Abnormal: Continuity.
NOTE: When testing the magnetron, be sure to install the magnetron gasket
in the correct position and be sure that the gasket is in good condition.
Antenna
Gasket
Chassis
Filament