![LG MC2841SPS Service Manual Download Page 29](http://html.mh-extra.com/html/lg/mc2841sps/mc2841sps_service-manual_215678029.webp)
5-19
(TROUBLE 8) Display shows error mode
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Display shows
"F02"
No continuity
Continuity
Normal.
Abnormal.
Check the
thermistor
Defective thermistor
(Thermistor shorted)
Replace the
thermistor
Loose connection
Connect them
tightly
Check the
connnection
between
thermistor and
P.C.B. assembly
Defective
P.C.B Assembly
Replace the
P.C.B. assembly
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Display shows
"F01"
No continuity
Continuity
Normal.
Abnormal.
Check the
thermistor
Defective thermistor
(Thermistor opened)
Replace the
thermistor
Loose connection
Connect them
tightly
Check the
connnection
between
Thermistor and
P.C.B. assembly
Normal.
Abnormal.
Check the heater
Defective heater
(Heater opened)
Replace the
heater
Defective
P.C.B. Assembly
Replace the
P.C.B. Assembly
(TROUBLE 9) Oven seems to be in operation but no heating is produced in Micro Mode
CONDITION
CHECK
RESULT
CAUSE
REMEDY
No Output in Micro
Open
Check HV Fuse
HVD,HVC
First Replace Defective
Part MGT/HVC/HVD
Mode.
or MGT NG
Then Replace HV Fuse
Summary of Contents for MC2841SPS
Page 1: ...MODEL MC2841SPS ...
Page 9: ...SCHEMATIC DIAGRAM 4 3 Conv therostat ...
Page 31: ... 6 2 DOOR P ARTS 13581A ...
Page 32: ... 6 3 CONTROL PANEL PARTS 268711 23572A 23506A ...
Page 34: ... 6 5 LATCH BOARD PARTS 33052N 466001 466003 466001 43500A ...
Page 36: ... 6 7 BASE PLATE PARTS 56170D ...
Page 37: ......
Page 39: ......