![LG MC-806BLR Service Manual Download Page 21](http://html.mh-extra.com/html/lg/mc-806blr/mc-806blr_service-manual_215644021.webp)
5-11
COMPONENTS
TEST PROCEDURE
RESULTS
FUSE
(Wire leads removed.)
HEATER ELEMENT
(Wire leads removed.)
OVEN THERMOSTAT
MAGNETRON
THERMOSTAT
Check for continuity of the switch with a
Multi-meter.
NOTE : If the fuse is blown, check the primary, the secondary, and the monitor
switches, H.V.D. and H.V.C. before replacing the fuse.
If the fuse is blown by improper switch operation replace the defective
switch and the fuse at the same time.
Replace just the fuse if the switches operate normally.
NOTE: Make sure heater is fully cooled when tested.
Measure the resistance.
(Multi-meter scale: R x 1)
Normal:
*Grill heater
Approx. 40.7
Ω
(at 20 ~ 30
o
C)
Normal: more than 0.5M
Ω
Normal Abnormal
Measure the resistance with 500V-100M
Ω
insulation resistance meter.
0°C~Approx 150°C Approx 150°C
Summary of Contents for MC-806BLR
Page 9: ...SCHEMATIC DIAGRAM 4 3 ...
Page 31: ...6 2 13551A 13581A 14970A 14026A 13552A 15006A 13213A 14890A DOOR PARTS ...
Page 34: ...6 5 WSZ085 466001 43501A 466003 466001 43500A LATCH BOARD PARTS ...
Page 36: ...6 7 WSZ062 WSZ002 WTT030 948505 948505 63302A 56170D 647781 63303A 948506 BASE PLATE PARTS ...