![LG MC-805CLR Service Manual Download Page 21](http://html.mh-extra.com/html/lg/mc-805clr/mc-805clr_service-manual_215642021.webp)
5-11
COMPONENTS TEST
PROCEDURE
RESULTS
HEATER ELEMENT
(Wire leads removed)
FUSE
(Wire leads removed.)
Normal
Abnormal
0°c~Approx 150°C
Approx 150°C
OVEN THERMOSTAT
MAGNETRON
THERMOSTAT
Normal :
• Grill heater
Approx. 40.7
Ω
(at 20~30°C)
Normal : more than 0.5M
Ω
Measure the resistance with 500V-100M
Ω
insulation resistance meter.
Measure the resistance.
(Multi-meter scale : R x 1)
Check for continuity of the switch with a
Multi-meter.
NOTE : If the fuse is blown, check the primary, the secondary, and the monitor
switches, H.V.D. and H.V.C. before replacing the fuse.
If the fuse is blown by improper switch operation replace the defective
switch and the fuse at the same time.
Replace just the fuse if the switches operate normally.
NOTE : Make sure heater is fully cooled when tested.
Summary of Contents for MC-805CLR
Page 9: ...SCHEMATIC DIAGRAM 4 3 ...
Page 31: ...DOOR PARTS 6 2 13720D 13350F 13581A 14970A 14026A 13552A 15006A 13213A 14890A ...
Page 34: ...LATCH BOARD PARTS 6 5 WSZ085 466001 43501A 466003 466001 43500A ...
Page 36: ...BASE PLATE PARTS 6 7 WSZ062 WSZ002 WTT030 948505 948502 63302A 56170D 647781 63303A 948506 ...
Page 37: ...SCHEMATIC DIAGRAM OF P C B 8 1 ...