A. PRIMARY INTERLOCK SWITCH TEST
When the door release button is depressed slowly
with the door closed, an audible
click
should be
heard at the same time or successively at
intervals. When the button is released slowly, the
latches should activate the switches with an
audible
click
.
If the latches do not activate the switches when
the door is closed, the switches should be a
adjusted in accordance with the adjustment
procedure. Disconnect the wire lead from the
primary switch. Connect the ohmmeter leads to
the common (COM) and normally open (NO)
terminal of the switch. The meter should indicate
an open circuit in the door open condition.
When the door is closed, the meter should
indicate a closed circuit.
When the primary switch operation is abnormal,
make the necessary adjustment or replace the
switch only with the same type of switch.
B. SECONDARY INTERLOCK SWITCH TEST
Disconnect the wire lead from the secondary
switch.
Connect the ohmmeter leads to the common
(COM) and normally open (NO) terminals of the
switch. The meter should indicate a open circuit in
the door open condition. When the door is closed,
meter should indicate an closed circuit. When the
secondary switch operation is abnormal, make
the necessary adjustment or replace the switch
only with the same type of switch.
C. MONITOR SWITCH TEST
Disconnect the wire lead from the monitor switch.
Connect the ohmmeter leads to the common
(COM) and normally closed (NC) terminals of the
switch. The meter should indicate closed circuit in
the door open condition. When the door is closed,
meter should indicate an open circuit. When the
monitor switch operation is abnormal, replace with
the same type of switch.
NOTE: After repairing the door or the interlock
system, it is necessary to do this continuity
test before operating the oven.
5-7
WARNING : FOR CONTINUED PROTECTION AGAINST EXCESSIVE RADIATION
EMISSION, REPLACE ONLY WITH IDENTICAL REPLACEMENT PARTS.
TYPE NO. SZM-V 16-FA-63 OR VP-533A-OF FOR PRIMARY SWITCH
TYPE NO. SZM-V 16-FA-62 OR VP-532A-OF FOR MONITOR SWITCH
TYPE NO. SZM-V 16-FA-63 OR VP-533A-OF FOR SECONDARY SWITCH
TYPE NO. SZM-V 16-FA-63 OR VP-533A-OF FOR GRILL CONTROL SWITCH
INTERLOCK CONTINUITY TEST
COMPONENTS
TEST PROCEDURE
RESULTS
SWITCHES
Check for continuity of the switch
Door
Door
(Wire leads removed)
with a Multi-meter
open
closed
Primary
Switch
Monitor
Switch
COM
NO
COM
NO
NC
COM
COM
NO
Secondary
Switch
Grill Control
Switch
NOTE :
After checking for the continuity of switches, make sure that are
correctly connected.
Summary of Contents for MC-7684B
Page 9: ...SCHEMATIC DIAGRAM 4 3 ...
Page 30: ...6 2 15006A 13552A 14890A 13213A 13720D 14026A 14970A WTP018 13581A 13650A DOOR PARTS EV ...
Page 33: ...6 5 WSZ085 466001 43501A 466003 466001 44510A 43500A 466001 LATCH BOARD PARTS EV ...
Page 35: ...6 7 63302A 56170D 63303A WSZ002 WTT021 647781 WTT030 BASE PLATE PARTS EV ...
Page 36: ......