5-19
(TROUBLE 8) Display shows error mode
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Display shows
"E01"
No continuity
Continuity
Normal.
Abnormal.
Check the
thermistor
Defective thermistor
(Thermistor shorted)
Replace the
thermistor
Loose connection
Connect them
tightly
Check the
connnection
between
thermistor and
P.C.B. assembly
Defective
P.C.B Assembly
Replace the
P.C.B. assembly
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Display shows
"E02"
No continuity
Continuity
Normal.
Abnormal.
Check the
thermistor
Defective thermistor
(Thermistor opened)
Replace the
thermistor
Loose connection
Connect them
tightly
Check the
connnection
between
Thermistor and
P.C.B. assembly
Normal.
Abnormal.
Check the heater
Defective heater
(Heater opened)
Replace the
heater
Defective
P.C.B. Assembly
Replace the
P.C.B. Assembly