LG MB8811C1 User Manual Download Page 8

                                                                 

   

 

 

 

STATEMENT and Warning 

 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 

conditions: (1) This device may not cause harmful interference, and (2) this device must accept 

any interference received, including interference that may cause undesired operation. 

FCC Caution: Any changes or modifications not expressly approved by the party responsible for 

compliance could void the user's authority to operate this equipment. 

   

This transmitter must not be co-located or operating in conjunction with any other antenna or 

transmitter. 

 

FCC RF Radiation Exposure Statement 

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled 

environment. This equipment should be installed and operated with minimum distance 20cm 

between the radiator & your body. 

 

IC 

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject 

to the following two conditions: (1) this device may not cause interference, and (2) this device 

must accept any interference, including interference that may cause undesired operation of the 

device. 

This equipment complies with IC radiation exposure limits set forth for an uncontrolled 

environment. This equipment should be installed and operated with minimum distance 20cm 

between the radiator and your body. 

French: 

Cet appareil radio est conforme au CNR-210 d’Industrie Canada. L’utilisation de ce dispositif est 

autorisée seulement aux deux conditions suivantes : (1) il ne doit pas produire de brouillage, et (2) 

l’utilisateur du dispositif doit être prêt à accepter tout brouillage radioélectrique reçu, même si ce 

brouillage est susceptible de compromettre le fonctionnement du dispositif. 

Cet équipement est conforme aux limites d’exposition aux rayonnements IC établies pour un 

environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 

cm de distance entre la source de rayonnement et votre corps. 

 

Summary of Contents for MB8811C1

Page 1: ...ed RF baseband controller etc SPECIFICATION Main Chips CSR8811 Standards Bluetooth 4 0 BLE Frequency Band 2402 2480 MHz Tx Power 7mW Rx Sensitivity 70dBm BER 0 1 Distance 10m open space Power Voltage 3 3V Dimension 18 6ⅹ31 2 ⅹ3 4 mm Environmental Range Operation temperature 10 70 Modulation mode GFSK 8DPSK κ 4 DQPSK Communication method FHSS ...

Page 2: ...0 3 6V 3 TXD O Bluetooth UART Serial Output 4 RTS O Bluetooth UART Request to Send Active low request 5 RXD I Bluetooth UART Serial Input 6 7 8 12 GND Ground 9 SDA I O I2C interface DATA 10 SCL O I2C interface Clock 11 RESET I Reset if low Input debounced so must be low for 5ms to cause a reset 1 VDD 2 RESET 3 RTS 4 CTS 5 TXD 6 GND 7 RXD 8 GND 9 SCL 10 SDA ...

Page 3: ...V 3 TXD O Bluetooth UART Serial Output 4 RTS O Bluetooth UART Request to Send Active low request 5 RXD I Bluetooth UART Serial Input 6 7 8 12 GND Ground 9 SDA I O I2C interface DATA 10 SCL O I2C interface Clock 11 RESET I Reset if low Input debounced so must be low for 5ms to cause a reset 2 VDD 11 RESET 4 RTS 1 CTS 3 TXD 5 RXD 6 GND 10 SCL 9 SDA 8 GND 7 GND 12 GND ...

Page 4: ... Mark Dimension Mark Dimension Mark Dimension Mark Dimension A 18 60 0 3 D 3 90 0 2 G 2 0 0 2 J 6 4 0 2 M 3 4 0 2 B 31 20 0 3 E 8 40 0 2 H 1 9 0 2 K 4 9 0 2 N 5 0 0 2 C 9 70 0 3 F 2 0 0 3 I 0 8 0 1 L 2 6 0 2 O 5 1 0 2 Unit mm ...

Page 5: ...Supply Voltage 3 0V 3 6V DCV Operation Temperature 10 70 Current consumption Parameter Connection Type Avg Peak Unit Page scan Time interval 1 28s 2 mA Inquiry and Page scan Time interval 1 28s 2 3 mA ACL No data transfer Master 10 mA ACL data transfer Master 32 mA Input Output Characteristics Parameter Min Max Unit VIL Input Voltage Low 0 4 0 8 V VIH Input Voltage High 0 7 VDD VDD 0 4 V VOL Outpu...

Page 6: ... Emission 30MHz 1GHz 36 dBm 1GHz 12 75GHz 30 dBm 1 8GHz 1 9GHz 47 dBm 5 1GHz 5 3GHz 47 dBm Modulation Characteristic F1avg 140 175 KHz F2max 115 KHz F2avg F1avg 80 Initial Carrier Frequency Tolerance DH1 packet 75 75 KHz Carrier Frequency Drift DH5 packet 25 25 KHz Receiver Performance Parameter Condition Min Type Max Unit Sensitivity at 0 1 BER Single slot DH1 packet 70 dBm Sensitivity at 0 1 BER...

Page 7: ... pdf 3 RF Test method RF Test tool is BlueTest exe at CSR bluesuite program You can see detail explanation from reference document reference document BlueTest Instruction Manual pdf Conformity Assessment Display Company name MCSLogic Model MCS Bluetooth Smart Device Module MB8811C1 Manufacture Year 2014 Manufacturer Manufacture Country MCSLogic Korea Operation of the radio equipment may cause prop...

Page 8: ...t RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance ...

Page 9: ...ay not be co located with any other transmitter or antenna As long as 2 conditions above are met further transmitter test will not be required However the OEM integrator is still responsible for testing their end product for any additional compliance requirements required with this module installed IMPORTANT NOTE In the event that these conditions can not be met for example certain laptop configur...

Page 10: ...his RF module in the user s manual of the end product which integrates this module CE Hereby declares that this WiFi module is in compliance with the essential requirements and other relevant provisions of R TTE Directive 1999 5 EC The standards for complying are as following ETSI EN 301 489 1 V1 9 2 2011 09 ETSI EN 301 489 17 V2 2 1 2012 09 ETSI EN 300 328 V1 8 1 2012 06 EN 62311 2008 EN 60950 1 ...