5-11
COMPONENTS
TEST PROCEDURE
RESULTS
TIMER MOTOR
(Wire leads removed)
FAN MOTOR
(Wire leads removed)
TURNTABLE
MOTOR
(Wire leads removed)
Check for continuity of timer motor with an
ohm-meter.
(Remove wire leads from timer motor)
Measure the resistance.
(Ohm-meter scale: R x 1)
Measure the resistance.
(Ohm-meter scale: R x 1000)
Normal:
Abnormal:
∞
or several
Ω
Normal: Approx. 100~200
Ω
Abnormal:
∞
or several
Ω
NOTE : • A MICROWAVE LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS
SERVICED FOR ANY REASON.
• MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION.
• WHEN REMOVING THE WIRE LEADS FROM THE PARTS, BE SURE TO GRASP THE
CONNECTOR, NOT THE WIRES.
A
B
C
Turn On Turn Off
A
B
Grill Switch
Microwave Switch
Approx. 22 K
Ω
Note : A is timer ON, OFF
switch.
B is power supply
terminal of the timer
motor.
A ~ B A ~ C
30 ~ 50
Ω
300~500
Ω
A
B
Summary of Contents for MB-393T
Page 27: ...6 2 13536A 13581A 13552A 13213A 13352A 13720D 14970A 14026A 13650A DOOR PARTS ...
Page 28: ...6 3 24781T 26549T WTP004 249401 23572A 249402 CONTROL PANEL PARTS ...
Page 30: ...6 5 466003 466001 43501A 43500A 44510A 466001 WSZ085 LATCH BOARD PARTS ...
Page 32: ...6 7 56170D 63302A 63303A WTT021 WSZ002 65006B 948501 BASE PLATE PARTS ...