D. PCB ASSEMBLY REMOVAL
1) Remove the control panel assembly from the
cavity. (Refer to control panel assembly removal
on previous page.)
2) Remove screws which hold the PCB SUB
ASSEMBLY to the control panel.
3) Disconnect the flat cable from the PCB SUB
ASSEMBLY and take off the PCB SUB ASSEMBLY.
E. DOOR MAIN ASSEMBLY REMOVAL
1) Open the door.
2) Remove the choke cover very carefully with a flat-blade
screwdriver.
CAUTION: Be careful not to damage door seal plate
by screwdriver.
3) Lift up and push the door.
NOTE:
1. After replacing the door, be sure to check that the
primary switch, monitor switch, and secondary switch
operate normally.
2. After replacing the door, check for microwave energy
leakage with a survey meter. Microwave energy must
be below the limit of 4 mW/cm. (with a 275 ml water
load)
3. When mounting the door assembly to the oven
assembly, be sure to adjust the door assembly parallel
to the chassis. Also, adjust so the door has no play
between the inner door surface and oven frame
assembly. If the door assembly is not mounted
properly, microwaves may leak from the clearance
between the door and the oven.
5-4
Door seal plate
Key
Membrane
Door Open
Button
Release
Lever
Button
Spring
Control Panel
PCB Sub Asm
Remove door
Remove choke cover
Spacer
Summary of Contents for MB-314XB
Page 28: ...6 2 13213A 13552A 13536A 14026A 14970A 13581A 15006A 14890A 13720D DOOR PARTS EV ...
Page 29: ...6 3 23506A 268711 WTT028 24781M 24510L 250201 23572A 24970A CONTROLLER PARTS EV ...
Page 31: ...6 5 LATCH BOARD PARTS EV WSZ085 466001 466003 466001 43500A 43501A ...
Page 34: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Page 35: ...8 2 PRINTED CIRCUIT BOARD ...
Page 36: ......