- 38 -
4. Temperature Environment Sensor Failure
No Checking Flow
Result & SVC Action
1
2
3
Check if there is a loose connection on CON3.
Unplug the PCB connectors and test the resistance
between the wires
"Brown and Brown"
on CON3
as shown in the image.
1. Remove the cover hinge.
2. Cut the sensor and verify the value resistance.
Result
SVC Action
Connected
Go to 2
Loose
Connect firmly, and
try again.
Problem persists?
Yes: Go to step 2.
No: Explain to customer.
SVC Action
0?
Short
OFF
Open
Other Normal Check temperature and
resistance (Resistance
Table, page 54).
Go to 6
Result
Go to 3
Go to 4
2
1
SVC Action
0?
Short
OFF
Open
Result
Replace refrigerator.
Change sensor.