background image

18

INSTALLATION

If the water pressure from the reverse osmosis 

system is less than 20 psi or 138 kPa or 1.4 kgf/ cm

2

 

(takes more than 4 seconds to fill a cup of 7 oz or 

198 cc capacity):

 

Check to see if the sediment filter in the reverse 

osmosis system is blocked. Replace the filter if 

necessary.

 

Allow the storage tank on the reverse osmosis 

system to refill after heavy usage.

 

If the water pressure remains low, call a licensed, 

qualified plumber.

 

All installations must be in accordance with local 

plumbing code requirements.

Supplies Needed

 

Copper or PEX Tubing

, ¼ in. outer diameter, to 

connect the refrigerator to the water supply. Be sure 

both ends of the tubing are cut square. To determine 

how much tubing you need, measure the distance 

from the water valve on the back of the refrigerator 

to the water supply pipe. Then, add 8 feet (2.4 m). 

Be sure there is sufficient extra tubing (about 8 feet 

[2.4 m] coiled into 3 turns of about 10 in. [25 cm] 

diameter) to allow the refrigerator to move out from 

the wall after installation.

 

Power drill.

 

½ in. or adjustable wrench.

 

Flat-blade and Phillips-head screwdrivers.

 

Two ¼ in. outer diameter compression nuts and 

2 ferrules (sleeves)

 to connect the copper tubing to 

the shutoff valve and the refrigerator water valve.

 

If your existing copper water line has a flared fitting 

at the end, purchase an adapter (available at 

plumbing supply stores) to connect the water line 

to the refrigerator OR cut off the flared fitting with a 

tube cutter and then use a compression fitting.

 

Shutoff valve to connect to the cold water line. 

The shutoff valve should have a water inlet with a 

minimum inside diameter of 5/32 in. at the point of 

connection to the COLD WATER LINE. Saddle-type 

shutoff valves are included in many water supply 

kits. Before purchasing, make sure a saddle-type 

valve complies with your local plumbing codes.

NOTE

 

A self-piercing saddle type water valve should not 

be used.

Water Line Installation Instructions

WARNING

Electric Shock Hazard:

 

When using any electrical device (such as a 

power drill) during installation, be sure the device 

is battery-powered, double-insulated or grounded 

in a manner that will prevent the hazard of 

electric shock.

Install the shutoff valve on the nearest frequently 

used drinking water line.

1

Shut off the main water supply.

Turn on the nearest faucet to relieve the pressure 

on the line.

2

Choose the valve location.

Choose a location for the valve that is easily 

accessible. It is best to connect into the side of 

a vertical water pipe. When it is necessary to 

connect into a horizontal water pipe, make the 

connection to the top or side, rather than at the 

bottom, to avoid drawing off any sediment from 

the water pipe.

Summary of Contents for LSXC22396S

Page 1: ...REFRIGERATOR Read this owner s manual thoroughly before operating the appliance and keep it handy for reference at all times LSXS26396S LSXC22396S MFL67653459 Rev 02_030817 www lg com Copyright 2017 LG Electronics Inc All Rights Reserved ...

Page 2: ...g installation instructions first after purchasing this product or transporting it to another location Unpacking the Refrigerator Choosing the Proper Location Disassembling Assembling Connecting the Water Line Leveling and Door Alignment CAUTION Connect to a potable water supply only ...

Page 3: ...e products can damage the surface of your refrigerator Reinstall or adjust shelves as needed Refrigerator shelves are installed in the shipping position Reinstall shelves according to your individual storage needs Choosing the Proper Location Water Water supply must be easily connected for the automatic icemaker NOTE The water pressure must be 20 120 psi or 138 827 kPa or 1 4 8 4 kgf cm2 If the re...

Page 4: ...nce from adjacent items may result in lowered freezing capability and increased electricity consumption charges Allow at least 24 inches 610 mm in front of the refrigerator to open the doors and at least 2 inches 50 8 mm between the back of the refrigerator and the wall B A C D F G E M List LSXS26396S LSXC22396S A Depth without handle 33 2 5 848 mm 29 2 5 747 mm B Width 35 9 10 912 mm 35 9 10 912 ...

Page 5: ...nd handle using a 1 4 in Allen wrench and remove the mounting fasteners Assembling the Refrigerator Handles 1 Assemble the mounting fasteners 1 at both ends of the handle with a 1 4 in Allen rench 2 Place the handle on the door by fitting the handle footprints over the mounting fasteners and tightening the set screws 2 with a 3 32 in Allen wrench Removing Assembling the Doors If the entrance door ...

Page 6: ...ckwise 1 and lift the upper hinge 2 1 2 Hinge Lever Upper Hinge 4 Lift the door to remove it from the lower hinge pin Be careful to pull the water lines from behind the lower hinge pin Enough for the water feed tube to be completely pulled out water feed tube Lower Hinge CAUTION When lifting the hinge free of the latch be careful that the door does not fall forward Place the door inside facing up ...

Page 7: ...rd the inside Water hoses should be behind the leg to prevent damage Correct Incorrect Disassembling Assembling the Water Lines Collet Tube Insert line Clip Correct 2 Gently press the collet and insert the tube until only one line shows on the tube Correct Incorrect NOTE Water hoses should be cut with a clean straight edge to avoid leaks 3 Fit the top over the hinge lever latch and into place Rota...

Page 8: ...r supply line to the refrigerator Water banging in the pipes or water hammer in residential plumbing can cause damage to refrigerator parts and lead to water leakage or flooding Turn the icemaker OFF if the refrigerator will be used before the water line is connected Do not install the icemaker tubing in areas where the ambient temperatures fall below freezing WARNING Connect to a potable water su...

Page 9: ...valve If your existing copper water line has a flared fitting at the end purchase an adapter available at plumbing supply stores to connect the water line to the refrigerator OR cut off the flared fitting with a tube cutter and then use a compression fitting Shutoff valve to connect to the cold water line The shutoff valve should have a water inlet with a minimum inside diameter of 5 32 in at the ...

Page 10: ...ng washer begins to swell Pipe Clamp Clamp Screw Washer Inlet End NOTE Do not over tighten clamp or you may crush the tubing 6 Route the tubing Route the tubing between the cold water line and the refrigerator Route the tubing through a hole drilled in the wall or floor behind the refrigerator or adjacent base cabinet as close to the wall as possible NOTE Be sure there is sufficient extra tubing a...

Page 11: ... line connections Leveling and Door Alignment Leveling The refrigerator has two front leveling legs Adjust the legs to alter the tilt from front to back or side to side If the refrigerator seems unsteady or the doors do not close easily adjust the refrigerator s tilt using the instructions below 1 Turn the leveling leg to the left to raise that side of the refrigerator or to the right to lower it ...

Page 12: ...n the Power After installing plug the refrigerator s power cord into a 3 prong grounded outlet and push the refrigerator into the final position CAUTION Connect to a rated power outlet Have a certified electrician check the wall outlet and wiring for proper grounding Do not damage or cut off the ground terminal of the power plug Position the Rrigerator Arrange the coil of tubing so that it does no...