INST
ALLA
TION OF INDOOR & OUTDOOR UNIT
Read completely, then follow step by step.
Ca
pa
cit
y is
ba
se
d o
n s
ta
nd
ard
le
ng
th
an
d m
ax
im
um
allowance length is on the basis of reliability.
Oil trap should be installed every 5~7 meters.
In case more than 5m
A
Indoor unit
Oil trap
Outdoor unit
A
Indoor unit
Outdoor unit
A
Do not
have any
heat or
steam near
the
unit.
Se
le
ct
a p
la
ce
wh
er
e t
he
re
ar
e n
o
obstacles in
front of
the unit.
Make sure
that condensation
drainage
can be
conveniently routed
away.
Do not
install near
a doorway
.
Ensure that
the space
around the
left and
right of
the unit
is more
than 100mm.
The
unit should
be installed
as high
on the
wall as
possible, allowing
a minimum
of
200mm from
ceiling.
Use a
stud finder
to locate
studs to
prevent unnecessary
damage to
the wall.
More than 100mm
More than 200mm
More than 2300mm
More than 100mm
Install the indoor unit on the wall where the height
from the floors more than 2300 mm.
B
If an
awning is
built over
the unit
to
prevent direct
sunlight or
rain exposure,
make sure
that heat
radiation from
the
condenser is
not restricted.
Ensure that
the space
around the
back
and sides
is more
than 300mm.
The front
of
the unit
should have
more than
700mm of
space.
Do not
place animals
and plants
in the
path of
the warm
air.
T ake the air conditioner weight into
account and select a place where noise
and vibration are minimum.
Select a place so that the warm air and
noise from the air conditioner do not
disturb neighbors.
Select the best location
Indoor Unit
CAUTION
Outdoor Unit
If the
outdoor unit
is installed
on a
roof structure,
be
sure to
level the
unit. Ensure
the roof
structure and
anchoring method
are adequate
for the
unit location.
Consult local
codes regarding
rooftop mounting.
Roo
ftop Inst
allation
Piping length and elevation
CAUTION
INSTALL
ATION
8
B
Capacity
(Btu/h)
18K (5 star)
24K Cooling
24K, 26K
Cooling & Heat Pump
5/8"
3/8"
3 to 5
Pipe Size
GAS
LIQUID
Standard
Length
(m)
1/2"
1/4"
1/4"
3 to 5
3 to 5
20
20
20
20
5/8"
1/4"
3 to 5
20
30
20
30
Max.
length
(m)
A
Additional
Refrigerant
(g/
m)
9K
3/8"
9K, 12K,
18K (2,3 star)
18K Heat Pump